欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM9312-UC 参数 Datasheet PDF下载

PM9312-UC图片预览
型号: PM9312-UC
PDF下载: 下载PDF文件 查看货源
内容描述: 增强TT1 ™交换机结构 [ENHANCED TT1⑩ SWITCH FABRIC]
分类和应用:
文件页数/大小: 343 页 / 5229 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM9312-UC的Datasheet PDF文件第114页浏览型号PM9312-UC的Datasheet PDF文件第115页浏览型号PM9312-UC的Datasheet PDF文件第116页浏览型号PM9312-UC的Datasheet PDF文件第117页浏览型号PM9312-UC的Datasheet PDF文件第119页浏览型号PM9312-UC的Datasheet PDF文件第120页浏览型号PM9312-UC的Datasheet PDF文件第121页浏览型号PM9312-UC的Datasheet PDF文件第122页  
Released  
PMC-Sierra, Inc.  
PM9311/2/3/5 ETT1™ CHIP SET  
Data Sheet  
PMC-2000164  
ISSUE 3  
ENHANCED TT1™ SWITCH FABRIC  
2. Turn off the EPP Output Scheduler for cells coming from itself. This will ensure that the cell will  
stay in the virtual input queue in the egress buffers of the Dataslice.  
3. Bring up all AIB links and enable non-tdm traffic in the Scheduler for this port. Enable the EPP and  
take it out of LCS-2 Stop mode.  
4. Write to the Outstanding Scheduler Request Counter in the EPP for this VOQ.  
This will cause a request to be made to the Scheduler which will immediately issue a grant to the  
EPP. The cell will be forwarded through the crossbar and back to the test port. The cell will then be  
stored in the egress queue but will not be forwarded to the linecard because the Output Scheduler  
was disabled in step 2.  
5. The CPU can read the cell that is waiting in the egress queue and check that it passed through  
OK.  
6. Repeat as needed.  
A number of variations can be done on this basic theme:  
Because the Output Scheduler in each EPP can be stopped on a per source port basis, then in  
step 1 the CPU can create a cell going to any egress port, not just to itself. This is possible even if  
the egress port is currently online with real traffic. Thus it is possible to verify the datapath from the  
new port to all other ports without interfering with existing flows.  
Do not turn off the Output Scheduler in step 2 (or unfreeze it after Step 6). The linecard can then  
verify that the cell is OK, thus testing more of the system.  
Send enough cells so that the egress queue fills up and backpressures the input. So after sending  
64 cells (OC-192 configuration) the egress queue should be full and thus prevent any more cells  
being sent to this queue.  
114  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
 复制成功!