S/UNI®-JET Data Sheet
Released
RINV
The RINV bit controls the logical inversion of the receive data stream before processing.
When RINV is a logic one, the received data is inverted before being processed by the pattern
detector. When RINV is a logic zero, the received data is not inverted
AUTOSYNC
The AUTOSYNC bit enables the automatic resynchronization of the pattern detector. The
automatic resynchronization is activated when six or more bit errors are detected in the last
64 bit periods. When AUTOSYNC is a logic one, the auto resync feature is enabled. When
AUTO SYNC is a logic zero, the auto sync feature is disabled, and pattern resynchronization
is accomplished using the MANSYNC bit.
MANSYNC
The MANSYNC bit is used to initiate a manual resynchronization of the pattern detector. A
low-to-high transition on MANSYNC initiates the resynchronization.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990267, Issue 3
238