S/UNI®-JET Data Sheet  
Released  
BEI  
The BEI bit indicates that one or more bit errors have been detected since the last time this  
register was read. When BEI is set to logic one, at least one bit error has been detected. BEI is  
set to logic zero when this register is read.  
XFERI  
The XFERI bit indicates that a transfer of pattern detector data has occurred. A logic one in  
this bit position indicates that the pattern receive registers, the bit counter holding registers  
and the error counter holding registers have been updated. This update is initiated by writing  
to one of the pattern detector register locations, or by writing to the S/UNI-JET Identification,  
Master Reset, and Global Monitor Update Register (006H). XFERI is set to logic zero when  
this register is read.  
OVR  
The OVR bit is the overrun status of the pattern detector registers. A logic one in this bit  
position indicates that a previous transfer (indicated by XFERI being logic one) has not been  
acknowledged before the next accumulation interval has occurred and that the contents of the  
pattern receive registers, the bit counter holding registers and the error counter holding  
registers have been overwritten. OVR is set to logic zero when this register is read.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990267, Issue 3  
240  