S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Issue  
No.  
4
Issue Date  
Details of Change  
Revealed COS_CC_DIS bit. Changed ATM_FIELD default to 0x00.  
Documented the fact that micro accesses can take as long as 40 cycles (for a  
read) or 90 cycles (for a write) in certain unusual cases. IBCIF and OBCIF  
default to odd parity, not even parity. PHY and Link blocks should be left in  
their default state when not being used. Typo to INSRST corrected. Direction  
of OBCIF, IBCIF clocks in figures 5,6,7,8 corrected. INSRDY documentation  
corrected to say that INSRDY stays high until a full cell has been written in.  
Halfsecclk input pin description altered to point correctly to the gen_halfsecclk  
bit. Documented the proper default state for the one-second CC, AIS, and  
Failure counts. Updated Boundary Scan description to match BSDL notation.  
Clarified that SDQ, PHY, and LINK interrupts are only asserted for interrupts  
that are enabled at the TSB level. Clarified that min freq for icif_clk and  
ocif_clk is 75 MHz, but that full bandwidth is only guaranteed at 104 MHz.  
Block size of 1 in Bypass SDQ explicitly not supported. OBCIF dropped-cells  
counter exposed, with a comment about the total BCIF capacity. VC_to_BCIF  
documented with the overflow mechanism. RxPhy calendar now states that it  
should be set to at least 64 entries, and preferably as close to 128 entries as  
possible, for maximum efficiency. Clarified that LBtoOCIF also overrides  
discarding due to LB_Route functionality. Clarified DLLRUN Bit functionality.  
Deleted XferErrToUP function; parity errors and rlp_err/tpp_err indications  
have no effect on ATM cells (beyond the assertion of an interrupt for a parity  
error). Recommended that the FLUSH bit be set for all disabled FIFOs, to  
eliminate spurious interrupts. Clarified that CntUndefOAM has no effect on  
OAMERRI. Increased maximum secondary search depth to 18. Changed  
PL3 loading to 30 pf to match the PL3 standard. Changed voltage rail spec. to  
+/-5%. Clarified that FM_to_UP does not control loopback cells, since  
LB_ROUTE does this. Added TM0 Details. Added thermal information.  
Specified max power at 3.0 W. Input High Current respecified to  
–15 uA/+650 uA on 3.3 V interface.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
7