PM6341 E1XC
DATA SHEET
PMC-910419
ISSUE 8
E1 FRAMER/TRANSCEIVER
signalling multiframe alignment signal, 0000, is substituted with 1111); when
set to logic 0, the signalling multiframe alignment signal is unchanged.
REMAIS:
The REMAIS bit controls the transmission of the remote Alarm Indication
Signal. A logic 1 in the REMAIS bit position causes bit 3 of NFAS frames to
be forced to logic 1; otherwise, bit 3 of NFAS frames is a logic 1.
MFAIS:
The MFAIS bit controls the transmission of the signalling multiframe Alarm
Indication Signal. A logic 1 in the MFAIS bit position causes the y-bit (bit 6) of
TS16 of frame 0 of the signalling multiframe to be forced to logic 1; otherwise,
the y-bit is a logic 1.
TS16AIS:
The TS16AIS bit controls the transmission of the Time Slot 16 Alarm
Indication Signal (all-ones in TS16). A logic 1 in the TS16AIS bit position
forces TS16 of all frames in the output stream to logic 1.
AIS:
The AIS bit controls the transmission of the Alarm Indication Signal
(unframed all-ones). A logic 1 in the AIS bit position forces the output
streams to logic 1.
When the E1XC is reset, the contents of this register are set to logic 0.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
171