PM6341 E1XC  
DATA SHEET  
PMC-910419  
ISSUE 8  
E1 FRAMER/TRANSCEIVER  
GENCRC FEBEDIS Source of International/National bits  
0
X
Bit position Si[1] in the International/National  
Control Register is used for the International bit  
in the frame alignment signal (FAS) frames and  
the Si[0] bit in the non-frame alignment signal  
(NFAS) frames if INDIS is logic 0. TPCM  
replaces Si[1:0] if INDIS is logic 1. Bit positions  
Sn[4:0] in the register are used for the National  
bits in NFAS frames.  
1
1
0
1
The calculated CRC bits are used for the  
International bit in the FAS frames and the  
generated CRC multiframe alignment signal and  
the FEBE bits are used for the International bit  
in the NFAS frames. Bit positions Sn[4:0] in the  
International/National Control Register are used  
for the National bits in NFAS frames.  
The calculated CRC bits are used for the  
International bit in the FAS frames and the  
generated CRC multiframe alignment signal is  
used for the International bit in the NFAS  
frames, with the Si[1:0] bits in the  
International/National Control Register used for  
the spare bits. Bit positions Sn[4:0] in the  
register are used for the National bits in NFAS  
frames.  
XDIS:  
If FDIS is logic 0 and SIGEN is logic 1, the XDIS bit controls the insertion of  
the Extra bits in TS16 of frame 0 of the signalling multiframe as follows. When  
XDIS is set to a logic 0, the contents of the Extra Bits Control Register are  
inserted into TS16, frame 0; when XDIS is a logic 1, the contents of the  
register are ignored and the values for those bits positions in the output  
stream are taken directly from the BTPCM stream. i.e., When XDIS and FDIS  
are logic 0, and SIGEN is logic 1, the X1,X3,X4 bit values from the Extra Bits  
Control Register are used for the Extra bits in TS16 of frame 0 of the  
signalling multiframe.  
When the E1XC is reset, the contents of this register are set to logic 0, except  
SIGEN and DLEN which are set to logic 1.  