欢迎访问ic37.com |
会员登录 免费注册
发布采购

CP1W-CIF12 参数 Datasheet PDF下载

CP1W-CIF12图片预览
型号: CP1W-CIF12
PDF下载: 下载PDF文件 查看货源
内容描述: SYSMAC CJ系列CJ2M CPU单元,脉冲I / O模块 [SYSMAC CJ-series CJ2M CPU Units, Pulse I/O Modules]
分类和应用: 脉冲
文件页数/大小: 30 页 / 3079 K
品牌: OMRON [ OMRON ELECTRONICS LLC ]
 浏览型号CP1W-CIF12的Datasheet PDF文件第12页浏览型号CP1W-CIF12的Datasheet PDF文件第13页浏览型号CP1W-CIF12的Datasheet PDF文件第14页浏览型号CP1W-CIF12的Datasheet PDF文件第15页浏览型号CP1W-CIF12的Datasheet PDF文件第17页浏览型号CP1W-CIF12的Datasheet PDF文件第18页浏览型号CP1W-CIF12的Datasheet PDF文件第19页浏览型号CP1W-CIF12的Datasheet PDF文件第20页  
CJ2M-CPU3@/-CPU1@/-MD21@  
Specifications of Pulse Output Functions  
Position Control and Speed Control  
Item  
Specifications  
Number of Pulse Outputs  
Output mode  
Max. 4 outputs (Pulse Output 00 to 03)  
Continuous mode (for speed control) or independent mode (for position control)  
Positioning (independent mode) instructions PULS (886) and SPED (885), PULS (886) and ACC (888), or PULS2 (887) instruction  
Speed control (continuous mode)  
SPED (885) and ACC (888) instructions  
instructions  
Origin (origin search and origin return)  
ORG (889) instruction  
instructions  
Interrupt feeding instruction  
Output frequency  
IFEED (892) instruction  
1 pps to 100 kpps (1 pps units), two pulse outputs × 2 Pulse I/O Modules  
Frequency acceleration and deceleration  
rates  
Set in increments of 1 pps for acceleration/deceleration rates from 1 to 65,535 pps (every 4 ms).  
The acceleration and deceleration rates can be set independently only with the PLS2 (887) instruction.  
Changing SVs during instruction execution The target frequency, acceleration/deceleration rate, and target position can be changed.  
Pulse output method  
CW/CCW or pulse + direction  
Relative coordinates: 0000 0000 to 7FFF FFFF hex (Accelerating or decelerating in either direction: 2,147,483,647)  
Absolute coordinates: 8000 0000 to 7FFF FFFF hex (2,147,483,648 to 2,147,483,647)  
Number of output pulses  
Absolute coordinates are specified automatically when the origin location has been defined by changing the pulse  
output PV with the INI (880) instruction or performing an origin search with the ORG(889) instruction. Relative  
coordinates must be used when the origin is undefined.  
Relative/absolute coordinate specifications  
for pulse output PVs  
The pulse type can be specified with an operand in the PULS (886) or PLS2 (887) instruction.  
Absolute pulses can be used when absolute coordinates are specified for the pulse output PV, i.e. the origin location  
has been defined. Absolute pulse cannot be used when relative coordinates are specified, i.e., when the origin location  
is undefined. An instruction error will occur.  
Relative pulse/absolute pulse specifications  
Pulse output PV's storage location  
The following Auxiliary Area words contain the pulse output PVs  
Pulse output 0: A277 (leftmost 4 digits) and A276 (rightmost 4 digits)  
Pulse output 1: A279 (leftmost 4 digits) and A278 (rightmost 4 digits)  
Pulse output 2: A323 (leftmost 4 digits) and A322 (rightmost 4 digits)  
Pulse output 3: A325 (leftmost 4 digits) and A324 (rightmost 4 digits)  
The PVs are refreshed during regular I/O refreshing.  
Variable-duty Pulse Outputs (PWM)  
Item  
Specifications  
Number of PWM Outputs  
Duty ratio  
Max. 4 outputs (PWM Output 00 to 03)  
0.0% to 100.0% in 0.1% increments  
Frequency  
0.1 Hz to 6,553.5 Hz (Set in 0.1-Hz increments.)  
1 Hz to 32,800 Hz (Set in 1-Hz increments.)  
Output mode  
Instruction  
Continuous Mode  
PWM (891) instruction  
16  
 复制成功!