FEDL87V5002-01
OKI Semiconductor
ML87V5002
When the sampling frequency is 192kHz, the frequency of 128 times is 24.576 MHz. In this case, only this
frequency can be selected.
LRCKI0 to LRCKI3 and BCKI0 toBCKI3 must synchronize with SYSCLK. As long as the synchronization is
maintained, the phase with SYSCLK is irrelevant.
I2C Address
This LSI can set two types of I2C addresses by the setting of MODE0 to MODE2.
• The I2C address is 0x8C/8D when MODE0 = ‘0’, MODE1 = ‘0’, and MODE2 = ‘0’
• The I2C address is 0x8E/8F when MODE0= ‘1’, MODE1 = ‘0’, and MODE2 = ‘0’
Modes other than those indicated above are not allowed since they are test modes of this LSI.