Freescale Semiconductor, Inc.
M
P
X
Y
8
0
2
0
A
Operating Range
The limits normally expected in the application which define range of operation.
Characteristic
Symbol
Min
Typ
Max
Units
Supply Voltage
V
DD
2.1
3.0
3.6
V
Operating Temperature Range
Standard Temperature Range
T
–40
T
H
+125
L
T
A
—
°C
Supply Current Drain
Standby Mode
–40°C to +85°C
I
I
I
—
—
—
0.6
0.8
1.5
0.9
1.2
2.2
µA
µA
µA
stby
stby
stby
+85°C to +100°C
+100°C to +125°C
Read Mode
–40°C to +125°C
Measure Temperature Mode
–40°C to +125°C
Measure Pressure Mode
–40°C to +10°C
I
—
—
400
400
600
600
µA
µA
read
I
temp
I
I
I
—
—
—
1400
1300
1200
1800
1700
1700
µA
µA
µA
press
press
press
+10°C to +60°C
+60°C to +125°C
Motorola Sensor Device Data
7
For More Information On This Product,
Go to: www.freescale.com