MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>  
PS21265-P/AP  
TRANSFER-MOLD TYPE  
INSULATED TYPE  
MECHANICAL CHARACTERISTICS AND RATINGS  
Parameter  
Limits  
Condition  
Recommended : 1.18 N·m  
Unit  
Min.  
Typ.  
Max.  
Mounting torque  
Weight  
Mounting screw : M4  
0.98  
1.47  
N·m  
g
µm  
54  
(
)
Heat-sink flatness  
Note 6  
–50  
100  
Note 6 :  
Measurement point  
3mm  
+
Place to contact  
a heat sink  
Heat sink  
+
Heat sink  
RECOMMENDED OPERATION CONDITIONS  
Symbol  
Parameter  
Supply voltage  
Recommended value  
Condition  
Unit  
Min.  
Typ.  
Max.  
VCC  
Applied between P-N  
Applied between VP1-VPC, VN1-VNC  
Applied between VUFB-VUFS, VVFB-VVFS, VWFB-VWFS  
0
13.5  
13.0  
–1  
300  
15.0  
15.0  
400  
16.5  
18.5  
1
V
V
VD  
Control supply voltage  
Control supply voltage  
VD, VDB  
Control supply variation  
VDB  
V
V/µs  
µs  
2
tdead  
fPWM  
Arm shoot-through blocking time For each input signal, TC 100°C  
PWM input frequency  
TC 100°C, Tj 125°C  
20  
kHz  
VCC = 300V, VD = VDB = 15V,  
P.F = 0.8, sinusoidal PWM  
TC 100°C, Tj 125°C (Note 7)  
fPWM = 5kHz  
fPWM = 15kHz  
14.0  
IO  
Allowable r.m.s. current  
Arms  
9.5  
0.3  
PWIN(on)  
(Note 8)  
Below rated current  
200 VCC 350V,  
1.4  
2.5  
13.5 VD 16.5V,  
µs  
Minimum input pulse width  
VNC variation  
13.0 VDB 18.5V,  
–20°C TC 100°C,  
N-line wiring inductance less  
Between rated current and  
1.7 times of rated current  
PWIN(off)  
VNC  
Between 1.7 times and  
(Note 9)  
2.0 times of rated current  
3.0  
than 10nH  
between VNC-N (including surge)  
–5.0  
V
5.0  
Note 7: The Allowable r.m.s. current value depends on the actual application conditions.  
8: Input signal with ON pulse width less than PWIN(on) might make no response.  
9: IPM might make no response or response delay to next turn-on pulse if off-pulse width is less than PWIN(off). (Please refer to Fig. 4)  
Please refer to Fig. 9 for recommended wiring method too.  
Oct. 2005  