MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>  
PS21265-P/AP  
TRANSFER-MOLD TYPE  
INSULATED TYPE  
THERMAL RESISTANCE  
Limits  
Symbol  
Parameter  
Condition  
Unit  
Min.  
Typ.  
Max.  
1.95  
Rth(j-c)Q  
Rth(j-c)F  
Rth(c-f)F  
Inverter IGBT part (per 1/6 module)  
°C/W  
°C/W  
°C/W  
Junction to case thermal  
resistance  
(Note 3)  
Inverter FWDi part (per 1/6 module)  
3.00  
Contact thermal resistance  
0.067  
Case to fin (per 1 module) thermal grease applied  
Note 3 : Grease with good thermal conductivity should be applied evenly with a thickness of about +100µm~+200µm on the contact surface  
of DIP-IPM and heat-sink.  
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise noted)  
INVERTER PART  
Limits  
Symbol  
VCE(sat)  
Parameter  
Condition  
Unit  
V
Min.  
Typ.  
Max.  
2.05  
2.15  
2.00  
1.85  
VD = VDB = 15V  
VIN = 5V  
IC = 20A, Tj = 25°C  
IC = 20A, Tj = 125°C  
Tj = 25°C, –IC = 20A, VIN = 0V  
1.55  
1.65  
1.50  
1.25  
0.30  
0.40  
1.50  
0.50  
Collector-emitter saturation  
voltage  
FWDi forward voltage  
VEC  
ton  
trr  
V
µs  
0.65  
µs  
µs  
µs  
µs  
VCC = 300V, VD = VDB = 15V  
5V  
tc(on)  
toff  
tc(off)  
IC = 20A, Tj = 125°C, VIN = 0  
0.60  
2.10  
0.80  
1
Switching times  
Inductive load (upper-lower arm)  
Tj = 25°C  
Tj = 125°C  
Collector-emitter cut-off  
current  
ICES  
mA  
VCE = VCES  
10  
CONTROL (PROTECTION) PART  
Symbol  
Parameter  
Limits  
Typ.  
Condition  
Unit  
Min.  
Max.  
7.00  
0.55  
7.00  
0.55  
mA  
mA  
mA  
mA  
V
VD = VDB = 15V  
VIN = 5V  
Total of VP1-VPC, VN1-VNC  
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS  
Total of VP1-VPC, VN1-VNC  
ID  
Circuit current  
VD = VDB = 15V  
VIN = 0V  
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS  
4.9  
VFOH  
VFOL  
VSC(ref)  
IIN  
VSC = 0V, FO circuit pull-up to 5V with 10kΩ  
VSC = 1V, IFO = 1mA  
TC = –20~100°C, VD = 15V  
VIN = 5V  
Fault output voltage  
0.95  
0.52  
2.0  
V
V
Short circuit trip level  
Input current  
0.45  
1.0  
10.0  
10.5  
10.3  
10.8  
1.0  
2.1  
0.8  
(Note 4)  
1.5  
mA  
V
Trip level  
12.0  
12.5  
12.5  
13.0  
UVDBt  
UVDBr  
UVDt  
UVDr  
tFO  
Reset level  
V
Control supply under-voltage  
protection  
Tj 125°C  
Trip level  
V
V
Reset level  
CFO = 22nF  
1.8  
2.3  
1.4  
ms  
V
(Note 5)  
Fault output pulse width  
ON threshold voltage  
OFF threshold voltage  
2.6  
Vth(on)  
Vth(off)  
Applied between UP, VP, WP-VPC, UN, VN, WN-VNC  
2.1  
V
Note 4: Short circuit protection is functioning only at the low-arms. Please select the external shunt resistance such that the SC trip-level is  
less than 2.0 times of the collector current rating (20A).  
5: Fault signal is output when the low-arms short circuit or control supply under-voltage protective functions operate. The fault output pulse-  
width tFO depends on the capacitance value of CFO according to the following approximate equation : CFO = 12.2 10-6 tFO [F].  
Oct. 2005  
 复制成功!