MT90220
Address (Hex):
Direct access
Reset Value (Hex):
098
00
Bit #
Type
Description
7
6
R/W
R/W
R/W
Writing a 1 forces the deselecting of the selected clock when it failed.
Reserved. Set to 0 for normal operation.
5:3
These 3 bits are used to select the source for the signal at PLLREF1:
The valid combinations are:
000: RXCK0
001: RXCK1
010: RXCK2
011: RXCK3
100: RXCK4
101: RXCK5
110: RXCK6
111: RXCK7
2:0
R/W
These 3 bits are used to select the source for the signal at PLLREF0:
The valid combinations are:
000: RXCK0
001: RXCK1
010: RXCK2
011: RXCK3
100: RXCK4
101: RXCK5
110: RXCK6
111: RXCK7
Table 84 - PLL Reference Control Register
70