MT90220
Address (Hex):
Direct access
11D
The value is updated on completion of the write action in the RX Load Values
register
20
Reset Value (Hex):
Bit #
Type
Description
7
6
5
R
R
R
LIF state of the link selected in the RX Load Values/Link Select register.
LCD state of the link selected in the RX Load Values/Link Select register.
A value of 1 means that the link selected in the RX Load Values/Link Select register is a
reference link for his IMA Group.
4:0
R
These bits report the link ID number for the link selected in the RX Load Values/Link
Select register.
Table 54 - RX Link ID Number Register
Address (Hex):
Direct access
11E
The value is updated on completion of the write action in the
RX Load Values register
00
Reset Value (Hex):
Bit #
Type
Description
7:6
5:4
3:2
R
R
R
Unused. Read all 0’s.
Frame length (value of M) of the link selected in the RX Load Values/Link Select register.
IMA Frame State:
00: Hunt
01: Presync
10: Sync.
11: Stuffed Frame event.
1:0
R
Cell Delineation State:
00: Hunt
01: Presync
10: Sync.
11: Unused.
Table 55 - RX State Register
56