MT90220
7.5 RX ICP Cell Registers Description
Tables 56 to 60 describe the RX ICP registers
Address (Hex):
Direct access
Reset Value (Hex):
1C0
Access for RX link 3-0
00
Bit #
Type
Description
7:6
R/W
These 2 bits select the type of cells stored in the RX ICP Cell buffer for physical link 3.
00: valid RX ICP Cells with changes.
01: All valid RX ICP Cells.
10: All valid RX Cells.
11: No cell written into RX buffer.
5:4
3:2
1:0
R/W
R/W
R/W
These 2 bits select the type of cells stored in the RX ICP Cell buffer for physical link 2.
00: valid RX ICP Cells with changes.
01: All valid RX ICP Cells.
10: All valid RX Cells.
11: No cell written into RX buffer.
These 2 bits select the type of cells stored in the RX ICP Cell buffer for physical link 1.
00: valid RX ICP Cells with changes.
01: All valid RX ICP Cells.
10: All valid RX Cells.
11: No cell written into RX buffer.
These 2 bits select the type of cells stored in the RX ICP Cell buffer for physical link 0.
00: valid RX ICP Cells with changes.
01: All valid RX ICP Cells.
10: All valid RX Cells.
11: No cell written into RX buffer.
Table 56 - RX ICP Cell Type RAM Register 1
57