MT90220
Address (Hex):
Direct access
1C7
Write to bit 2:0 of this register to select the specific link RX ICP Cell FIFO. The
value is immediately updated for a read
00
Reset Value (Hex):
Bit #
Type
Description
7:6
5:4
3:2
1:0
2:0
R
R
R
R
W
Unused. Read all 0’s.
Level of RX ICP Cell FIFO.
FIFO write pointer position
FIFO read pointer position
Select link number for FIFO Status.
Table 59 - RX ICP Cell Level FIFO Status Register
Address (Hex):
1C3
Synchronized access Set Address for an indirect access to write to ICP Cell RAM
Reset Value (Hex):
00
Bit #
Type
Description
7
R/W
0: External SRAM Test Mode is disabled,
1: External SRAM Test Mode is enabled.
6
5
R/W
R/W
R/W
R/W
R/W
Reserved, write 0 for normal operation.
Reserved, write 0 for normal operation.
Reserved, write 0 for normal operation.
Reserved, write 0 for normal operation.
Reserved, write 0’s for normal operation.
4
3
2:0
Table 60 - Test Mode Enable Register
59