MH89760B
Preliminary Information
interfaces is selected as the synchronization source
by enabling its output through the Master Control
Word of the chosen interface. Phase-locked loop #2
will then generate ST-BUS clocks that are
synchronized to either the T1 network or the CEPT
network. Phase-locked loop #1 is configured to
generate the T1 transmit clock synchronized to the
ST-BUS. Therefore, if the ST-BUS is synchronized to
one network then the elastic buffer in the opposite
interfaces will perform controlled slips between that
network and the T1 to CEPT converter.
Magnetics Information
For supporting initial design activities, Mitel
Semiconductor has available the MH89760B
Magnetic Kit which contains the magnetics shown in
Figure 11. Alternatively, they are available directly
from the following manufacturer:
Filtran Ltd.
229 Colonnade Road
Nepean, Ontario
Canada K2E 7K3
Telephone: (613) 226-1626
Please refer to Figure 6 for the transformer part
numbers.
4-80