欢迎访问ic37.com |
会员登录 免费注册
发布采购

MT48LC4M16A2P-75G 参数 Datasheet PDF下载

MT48LC4M16A2P-75G图片预览
型号: MT48LC4M16A2P-75G
PDF下载: 下载PDF文件 查看货源
内容描述: SDR SDRAM MT48LC16M4A2 â ????梅格4 ×4× 4银行MT48LC8M8A2 â ???? 2梅格×8× 4银行MT48LC4M16A2 â ???? 1梅格×16× 4银行 [SDR SDRAM MT48LC16M4A2 – 4 Meg x 4 x 4 Banks MT48LC8M8A2 – 2 Meg x 8 x 4 Banks MT48LC4M16A2 – 1 Meg x 16 x 4 Banks]
分类和应用: 动态存储器
文件页数/大小: 83 页 / 3595 K
品牌: MICRON [ MICRON TECHNOLOGY ]
 浏览型号MT48LC4M16A2P-75G的Datasheet PDF文件第45页浏览型号MT48LC4M16A2P-75G的Datasheet PDF文件第46页浏览型号MT48LC4M16A2P-75G的Datasheet PDF文件第47页浏览型号MT48LC4M16A2P-75G的Datasheet PDF文件第48页浏览型号MT48LC4M16A2P-75G的Datasheet PDF文件第50页浏览型号MT48LC4M16A2P-75G的Datasheet PDF文件第51页浏览型号MT48LC4M16A2P-75G的Datasheet PDF文件第52页浏览型号MT48LC4M16A2P-75G的Datasheet PDF文件第53页  
64Mb: x4, x8, x16 SDRAM  
READ Operation  
Figure 19: Random READ Accesses  
T0  
T1  
T2  
T3  
T4  
T5  
CLK  
Command  
Address  
DQ  
READ  
READ  
READ  
READ  
NOP  
NOP  
Bank,  
Col n  
Bank,  
Col a  
Bank,  
Col x  
Bank,  
Col m  
DOUT  
DOUT  
DOUT  
DOUT  
CL = 2  
T0  
T1  
T2  
T3  
T4  
T5  
T6  
CLK  
READ  
READ  
READ  
READ  
NOP  
NOP  
NOP  
Command  
Address  
DQ  
Bank,  
Col n  
Bank,  
Col a  
Bank,  
Col x  
Bank,  
Col m  
DOUT  
DOUT  
DOUT  
DOUT  
CL = 3  
Transitioning data  
Don’t Care  
1. Each READ command can be issued to any bank. DQM is LOW.  
Note:  
Data from any READ burst can be truncated with a subsequent WRITE command, and  
data from a fixed-length READ burst can be followed immediately by data from a  
WRITE command (subject to bus turnaround limitations). The WRITE burst can be ini-  
tiated on the clock edge immediately following the last (or last desired) data element  
from the READ burst, provided that I/O contention can be avoided. In a given system  
design, there is a possibility that the device driving the input data will go Low-Z before  
the DQ go High-Z. In this case, at least a single-cycle delay should occur between the  
last read data and the WRITE command.  
The DQM input is used to avoid I/O contention, as shown in Figure 20 (page 50) and  
Figure 21 (page 51). The DQM signal must be asserted (HIGH) at least two clocks prior  
to the WRITE command (DQM latency is two clocks for output buffers) to suppress da-  
ta-out from the READ. After the WRITE command is registered, the DQ will go to High-Z  
(or remain High-Z), regardless of the state of the DQM signal, provided the DQM was  
active on the clock just prior to the WRITE command that truncated the READ com-  
mand. If not, the second WRITE will be an invalid WRITE. For example, if DQM was  
LOW during T4, then the WRITEs at T5 and T7 would be valid, and the WRITE at T6  
would be invalid.  
PDF: 09005aef80725c0b  
64mb_x4x8x16_sdram.pdf - Rev. U 05/13 EN  
Micron Technology, Inc. reserves the right to change products or specifications without notice.  
49  
© 1999 Micron Technology, Inc. All rights reserved.  
 复制成功!