MAX17047/MAX17050  
ModelGauge m3 Fuel Gauge  
devices are calibrated for current-measurement accu-  
racy at the factory. However, if the application requires,  
Current Register readings can be adjusted by changing  
the COFF and CGAIN register settings.  
Additionally, the device maintains a record of the mini-  
mum and maximum current measured by the device,  
and an average current over a time period defined by  
the host. Contents of the Current and AverageCurrent  
registers are 0000h until the first conversion cycle time  
period after IC power-up. The last values of the Current  
and AverageCurrent registers are maintained when the  
IC enters shutdown mode.  
MaxMinV  
Register (1Bh)  
CELL  
The MaxMinV  
register maintains the maximum and  
CELL  
minimum V  
register values since the last fuel-gauge  
reset or until reset by the host software. Each time the  
register updates, it is compared against these  
is larger than the maximum or less than  
the minimum, the corresponding value is replaced with  
the new reading. At power-up, the MaxV  
to 00h (the minimum) and the MinV  
FFh (the maximum). Therefore, both values are changed  
to the V register reading after the first update. Host  
software can reset this register by writing it to its power-  
up value of 00FFh. The maximum and minimum voltages  
are each stored as 8-bit values with a 20mV resolution.  
CELL  
V
CELL  
values. If V  
CELL  
value is set  
value is set to  
CELL  
CELL  
CELL  
Current Register (0Ah)  
While in active mode, the device periodically measures the  
voltage between the CSN and CSP pins over a Q51.2mV  
range. The resulting data is stored as a two’s-complement  
value in the Current register every 175.8ms with an LSb value  
Figure 51 shows the MaxMinV  
register format.  
CELL  
Current Measurement  
While in active mode, the device periodically measures  
the voltage between the CSN and CSP pins over a  
Q51.2mV range. The resulting data is stored as a signed  
two’s-complement value in the Current register every  
of 1.5625FV/R  
. Voltages outside the minimum and  
SENSE  
maximum register values are reported as the minimum or  
maximum value. Figure 52 shows the Current register format  
and Table 3 shows the Sample Current register conversions.  
175.8ms with an LSb value of 1.5625FV/R  
. All  
SENSE  
MSB—ADDRESS 1Bh  
LSB—ADDRESS 1Bh  
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
MAX MAX MAX MAX MAX MAX MAX MAX  
MIN MIN MIN MIN MIN MIN MIN MIN  
MSb  
LSb  
MSb  
LSb  
UNITS: 20mV  
Figure 51. MaxMinV  
Register Format (Output)  
CELL  
Table 3. Sample Current Register Conversions  
SENSE  
RESISTOR (I)  
CGAIN  
REGISTER  
CURRENT REGISTER  
RESOLUTION (µA)  
CURRENT REGISTER MAXIMUM CELL  
FUNCTION  
RANGE (A)  
Q10.24  
Q5.12  
CAPACITY (Ah)  
0.005  
0.010  
0.020  
4000h  
4000h  
4000h  
312.50  
156.25  
78.125  
32.768  
Adjusting sense  
resistor to meet  
range and accuracy  
requirements  
16.384  
Q2.56  
8.192  
0.005  
0.010  
0.020  
7FFFh  
4000h  
2000h  
156.25  
156.25  
156.25  
Q5.12  
Q5.12  
Q5.12  
16.384  
16.384  
16.384  
Adjusting CGAIN to  
keep units constant  