欢迎访问ic37.com |
会员登录 免费注册
发布采购

MAX17050 参数 Datasheet PDF下载

MAX17050图片预览
型号: MAX17050
PDF下载: 下载PDF文件 查看货源
内容描述: ModelGauge立方米电量计 [ModelGauge m3 Fuel Gauge]
分类和应用: 仪表
文件页数/大小: 47 页 / 2597 K
品牌: MAXIM [ MAXIM INTEGRATED PRODUCTS ]
 浏览型号MAX17050的Datasheet PDF文件第31页浏览型号MAX17050的Datasheet PDF文件第32页浏览型号MAX17050的Datasheet PDF文件第33页浏览型号MAX17050的Datasheet PDF文件第34页浏览型号MAX17050的Datasheet PDF文件第36页浏览型号MAX17050的Datasheet PDF文件第37页浏览型号MAX17050的Datasheet PDF文件第38页浏览型号MAX17050的Datasheet PDF文件第39页  
MAX17047/MAX17050  
ModelGauge m3 Fuel Gauge  
S
in the CONFIG register and SACFG in the MiscCFG  
Status Register (00h)  
The Status register maintains all flags related to alert  
thresholds and battery insertion or removal. Figure 47  
shows the Status register format.  
S
register. Smn is set to 0 at power-up.  
Bi—Battery Insertion. This bit is set to a 1 when the  
device detects that a battery has been inserted into  
the system by monitoring the AIN pin. This bit must be  
cleared by system software to detect the next insertion  
event. Bi is set to 0 at power-up.  
POR—Power-On Reset. This bit is set to a 1 when the  
device detects that a software or hardware POR event  
has occurred. If the host detects that the POR bit has  
been set, the device should be reconfigured. See the  
Power-Up and Power-On Reset section. This bit must be  
cleared by system software to detect the next POR event.  
POR is set to 1 at power-up.  
Vmx—Maximum V  
set to a 1 whenever a V  
maximum V  
Threshold Exceeded. This bit is  
ALRT  
register reading is above the  
CELL  
value. This bit may or may not need to be  
ALRT  
cleared by system software to detect the next event. See  
V in the CONFIG register. Vmx is set to 0 at power-up.  
Bst—Battery Status. This bit is set to 0 when a battery  
is present in the system and set to 1 when the battery is  
removed. Bst is set to 0 at power-up.  
S
Tmx—Maximum T  
Threshold Exceeded. This bit is  
ALRT  
set to a 1 whenever a Temperature register reading is  
above the maximum T value. This bit may or may  
Vmn—Minimum V  
set to a 1 whenever a V  
Threshold Exceeded. This bit is  
ALRT  
ALRT  
not need to be cleared by system software to detect the  
register reading is below  
CELL  
next event. See T in the CONFIG register. Tmx is set to  
the minimum V  
value. This bit may or may not need  
S
ALRT  
0 at power-up.  
to be cleared by system software to detect the next  
event. See V in the CONFIG register. Vmn is set to 0 at  
power-up.  
S
Smx—Maximum SOC  
Threshold Exceeded. This bit  
ALRT  
is set to a 1 whenever SOC rises above the maximum  
SOC value. This bit may or may not need to be  
Tmn—Minimum T  
Threshold Exceeded. This bit is  
ALRT  
ALRT  
cleared by system software to detect the next event. See  
in the CONFIG register and SACFG in the MiscCFG  
set to a 1 whenever a Temperature register reading is  
below the minimum T value. This bit may or may not  
S
S
ALRT  
register. Smx is set to 0 at power-up.  
need to be cleared by system software to detect the next  
event. See T in the CONFIG register. Tmn is set to 0 at  
power-up.  
S
Br—Battery Removal. This bit is set to a 1 when the  
device detects that a battery has been removed from the  
system. This bit must be cleared by system software to  
detect the next removal event. Br is set to 0 at power-up.  
Smn—Minimum SOC  
Threshold Exceeded. This  
ALRT  
bit is set to a 1 whenever SOC falls below the minimum  
SOC value. This bit may or may not need to be  
ALRT  
X—Don’t Care. This bit is undefined and can be logic 0 or 1.  
cleared by system software to detect the next event. See  
MSB—ADDRESS 00h  
LSB—ADDRESS 00h  
Br  
Smx Tmx Vmx  
Bi  
Smn Tmn Vmn  
LSb  
X
X
X
X
Bst  
X
POR  
X
MSb  
MSb  
LSb  
Figure 47. Status Register Format (Input/Output)  
���������������������������������������������������������������� Maxim Integrated Products 35  
 复制成功!