欢迎访问ic37.com |
会员登录 免费注册
发布采购

LFEC33E-3FN672C 参数 Datasheet PDF下载

LFEC33E-3FN672C图片预览
型号: LFEC33E-3FN672C
PDF下载: 下载PDF文件 查看货源
内容描述: 的LatticeECP / EC系列数据手册 [LatticeECP/EC Family Data Sheet]
分类和应用:
文件页数/大小: 163 页 / 1036 K
品牌: LATTICE [ LATTICE SEMICONDUCTOR ]
 浏览型号LFEC33E-3FN672C的Datasheet PDF文件第18页浏览型号LFEC33E-3FN672C的Datasheet PDF文件第19页浏览型号LFEC33E-3FN672C的Datasheet PDF文件第20页浏览型号LFEC33E-3FN672C的Datasheet PDF文件第21页浏览型号LFEC33E-3FN672C的Datasheet PDF文件第23页浏览型号LFEC33E-3FN672C的Datasheet PDF文件第24页浏览型号LFEC33E-3FN672C的Datasheet PDF文件第25页浏览型号LFEC33E-3FN672C的Datasheet PDF文件第26页  
Architecture  
LatticeECP/EC Family Data Sheet  
Lattice Semiconductor  
Signed and Unsigned with Different Widths  
The DSP block supports different widths of signed and unsigned multipliers besides x9, x18 and x36 widths. For  
unsigned operands, unused upper data bits should be filled to create a valid x9, x18 or x36 operand. For signed  
two’s complement operands, sign extension of the most significant bit should be performed until x9, x18 or x36  
width is reached. Table 2-8 provides an example of this.  
Table 2-8. An Example of Sign Extension  
Unsigned  
9-bit  
Unsigned  
18-bit  
Two’s Complement  
Signed 9-Bits  
Two’s Complement  
Signed 18-bits  
Number Unsigned  
Signed  
0101  
+5  
-6  
0101  
0110  
000000101 000000000000000101  
000000110 000000000000000110  
000000101  
111111010  
000000000000000101  
111111111111111010  
1010  
OVERFLOW Flag from MAC  
The sysDSP block provides an overflow output to indicate that the accumulator has overflowed. When two  
unsigned numbers are added and the result is a smaller number then accumulator roll over is said to occur and  
overflow signal is indicated. When two positive numbers are added with a negative sum and when two negative  
numbers are added with a positive sum, then the accumulator “roll-over” is said to have occurred and an overflow  
signal is indicated. Note when overflow occurs the overflow flag is present for only one cycle. By counting these  
overflow pulses in FPGA logic, larger accumulators can be constructed. The conditions overflow signals for signed  
and unsigned operands are listed in Figure 2-23.  
Figure 2-23. Accumulator Overflow/Underflow Conditions  
000000011  
000000010  
000000001  
000000000  
3
2
1
0101111100  
0101111101 253  
252  
Carry signal is generated for  
one cycle when this  
254  
255  
256  
0101111110  
0101111111  
1010000000  
0
boundary is crossed  
111111111  
111111110  
111111101  
511  
510  
509  
1010000001 257  
1010000010  
258  
Unsigned Operation  
000000011  
+3  
+2  
+1  
0
-1  
-2  
-3  
0101111100  
0101111101 253  
0101111110  
0101111111  
252  
000000010  
000000001  
000000000  
111111111  
111111110  
111111101  
Overflow signal is generated  
for one cycle when this  
boundary is crossed  
254  
255  
1010000000  
1010000001  
1010000010  
256  
255  
254  
Signed Operation  
2-19  
 复制成功!