Operating Conditions
Page 33
f
For more information about programming and configuration support, refer to the
following documents:
■
■
■
■
■
Altera Programming Hardware Data Sheet
Programming Hardware Manufacturers
USB-Blaster Download Cable User Guide
ByteBlaster II Download Cable User Guide
EthernetBlaster Communications Cable User Guide
Operating Conditions
Table 18 through Table 22 list information about the absolute maximum ratings,
recommended operating conditions, DC operating conditions, and capacitance for
EPCS devices.
(1)
Table 18. Absolute Maximum Ratings
Symbol
Parameter
Condition
Min
Max
Unit
Supply voltage for EPCS1, EPCS4,
and EPCS16 devices
With respect to GND
–0.6
4.0
V
VCC
Supply voltage for EPCS64 and
EPCS128 devices
With respect to GND
With respect to GND
With respect to GND
–0.2
–0.6
–0.5
4.0
4.0
4.0
V
V
V
DC input voltage for EPCS1, EPCS4,
and EPCS16 devices
VI
DC input voltage for EPCS64 and
EPCS128 devices
IMAX
IOUT
PD
DC VCC or GND current
DC output current per pin
Power dissipation
—
—
—
–25
—
15
25
mA
mA
mW
C
—
54
TSTG
TAMB
TJ
Storage temperature
Ambient temperature
Junction temperature
No bias
Under bias
Under bias
–65
–65
—
150
135
135
C
C
Table 19. Recommended Operating Conditions
Symbol Parameter
VCC Supply voltage
Conditions
Min
2.7
–0.3
0
Max
Unit
V
(2)
3.6
VI
VO
TA
tR
Input voltage
With respect to GND
0.3 + VCC
V
Output voltage
Operating temperature
Input rise time
Input fall time
—
VCC
85
5
V
For industrial use
–40
—
C
ns
ns
—
—
tF
—
5
April 2014 Altera Corporation
Serial Configuration (EPCS) Devices Datasheet