欢迎访问ic37.com |
会员登录 免费注册
发布采购

E28F200B5B80 参数 Datasheet PDF下载

E28F200B5B80图片预览
型号: E28F200B5B80
PDF下载: 下载PDF文件 查看货源
内容描述: 智能5引导块闪存系列2 , 4 , 8兆比特 [SMART 5 BOOT BLOCK FLASH MEMORY FAMILY 2, 4, 8 MBIT]
分类和应用: 闪存存储内存集成电路光电二极管
文件页数/大小: 38 页 / 500 K
品牌: INTEL [ INTEL ]
 浏览型号E28F200B5B80的Datasheet PDF文件第15页浏览型号E28F200B5B80的Datasheet PDF文件第16页浏览型号E28F200B5B80的Datasheet PDF文件第17页浏览型号E28F200B5B80的Datasheet PDF文件第18页浏览型号E28F200B5B80的Datasheet PDF文件第20页浏览型号E28F200B5B80的Datasheet PDF文件第21页浏览型号E28F200B5B80的Datasheet PDF文件第22页浏览型号E28F200B5B80的Datasheet PDF文件第23页  
E
SMART 5 BOOT BLOCK MEMORY FAMILY  
Table 5. Command Codes and Descriptions (Continued)  
Description  
Code Device Mode  
50  
Clear Status The WSM can only set the program status and erase status bits in the status  
Register  
register to “1”; it cannot clear them to “0.”  
The status register operates in this fashion for two reasons. The first is to give the  
host CPU the flexibility to read the status bits at any time. Second, when  
programming a string of bytes, a single status register query after programming the  
string may be more efficient, since it will return the accumulated error status of the  
entire string. See Section 3.2.3.1.  
90  
Intelligent  
Identifier  
Puts the device into the intelligent identifier read mode, so that reading the device  
will output the manufacturer and device codes. (A0 = 0 for manufacturer,  
A0 = 1 for device, all other address inputs are ignored). See Section 3.2.2.  
Table 6. Command Bus Definitions  
First Bus Cycle  
Second Bus Cycle  
Command  
Note  
Oper  
Write  
Write  
Write  
Write  
Write  
Write  
Write  
Write  
Addr  
X
Data  
Oper  
Addr  
Data  
Read Array  
FFH  
90H  
Intelligent Identifier  
Read Status Register  
Clear Status Register  
Word/Byte Program  
Block Erase/Confirm  
Erase Suspend  
2,4  
3
X
Read  
Read  
IA  
X
IID  
X
70H  
SRD  
3
X
50H  
6,7  
5
PA  
BA  
X
40H/10H  
20H  
Write  
Write  
PA  
BA  
PD  
D0H  
B0H  
Erase Resume  
X
D0H  
ADDRESS  
DATA  
BA = Block Address  
IA = Identifier Address  
PA = Program Address  
X = Don’t Care  
SRD = Status Register Data  
IID = Identifier Data  
PD = Program Data  
NOTES:  
1. Bus operations are defined in Tables 3 and 4.  
2. IA = Identifier Address: A0 = 0 for manufacturer code, A0 = 1 for device code.  
3. SRD - Data read from Status Register.  
4. IID = Intelligent Identifier Data. Following the Intelligent Identifier command, two read operations access manufacturer and  
device codes.  
5. BA = Address within the block being erased.  
6. PA = Address to be programmed. PD = Data to be programmed at location PA.  
7. Either 40H or 10H commands is valid.  
8. When writing commands to the device, the upper data bus [DQ –DQ15] = X which is either VIL or VIH, to minimize current  
8
draw.  
19  
ADVANCE INFORMATION  
 复制成功!