Intel® Celeron® Processor for PGA370 up to 1.40 GHz on 0.13 µ Process  
Table 38. Boxed Processor Fan Heatsink Spatial Dimensions  
Dimensions (Inches)  
Fan Heatsink Length  
Min  
Typ  
Max  
Units  
3.14  
1.81  
2.6  
Inches  
Inches  
Inches  
Inches  
Inches  
Fan Heatsink Height  
Fan Heatsink Width  
Fan Heatsink height above motherboard  
Air Keepout Zones from end of Fan Heatsink  
0.29  
0.20  
0.30  
0.33  
Figure 31. Dimensions of Mechanical Step Feature in Heatsink Base  
0.043  
0.472  
Units = inches  
6.1.2  
Boxed Processor Heatsink Weight  
The boxed processor thermal cooling solution will not weigh more than 180 grams.  
6.2  
Thermal Specifications  
This section describes the cooling requirements of the thermal cooling solution utilized by the  
boxed processor.  
6.2.1  
Boxed Processor Cooling Requirements  
The boxed processor is directly cooled with a fan heatsink. However, meeting the processor’s  
temperature specification is also a function of the thermal design of the entire system and  
ultimately the responsibility of the system integrator. The processor temperature specification is  
found in Section 4.1 of this document. The boxed processor fan heatsink is able to keep the  
processor temperature within the specifications (see Table 30 in Section 4.1) in chassis that provide  
good thermal management.  
For the boxed processor fan heatsink to operate properly, it is critical that the airflow provided to  
the fan heatsink is unimpeded. Airflow of the fan heatsink is into the center and out of the sides of  
the fan heatsink. Airspace is required around the fan to ensure that the airflow through the fan  
heatsink is not blocked. Blocking the airflow to the fan heatsink reduces the cooling efficiency and  
decreases fan life. Figure 32 illustrate an acceptable airspace clearance for the fan heatsink. It is  
70  