XMC4500
XMC4000 Family
Electrical Parameters
t1
t2
t5
t4
t3
SCK
WA/
DOUT
Figure 22
USIC IIS Master Transmitter Timing
USIC IIS Slave Receiver Timing
Table 45
Parameter
Symbol
Values
Unit Note /
Test Condition
Min.
Typ.
Max.
Clock period
Clock HIGH
t6 SR
t7 SR
66.6
−
−
−
−
ns
ns
0.35 x
t6min
Clock Low
Set-up time
Hold time
t8 SR
t9 SR
0.35 x
t6min
−
−
−
−
−
−
ns
ns
ns
0.2 x
t6min
t
10 SR
0
t6
t7
t8
SCK
t9
t10
WA/
DIN
Figure 23
USIC IIS Slave Receiver Timing
Data Sheet
78
V1.0, 2013-01
Subject to Agreement on the Use of Product Information