PDF下载: 下载PDF文件 查看货源
内容描述: 16位/ 32位单芯片微控制器与32位性能 [16/32-Bit Single-Chip Microcontroller with 32-Bit Performance]
分类和应用: 微控制器
文件页数/大小: 110 页 / 2339 K
品牌: INFINEON [ Infineon ]
 浏览型号XC2000的Datasheet PDF文件第35页浏览型号XC2000的Datasheet PDF文件第36页浏览型号XC2000的Datasheet PDF文件第37页浏览型号XC2000的Datasheet PDF文件第38页浏览型号XC2000的Datasheet PDF文件第40页浏览型号XC2000的Datasheet PDF文件第41页浏览型号XC2000的Datasheet PDF文件第42页浏览型号XC2000的Datasheet PDF文件第43页  
XC2287 / XC2286 / XC2285  
XC2000 Family Derivatives  
Preliminary  
Functional Description  
1024 bytes (2 × 512 bytes) of the address space are reserved for the Special Function  
Register areas (SFR space and ESFR space). SFRs are word wide registers which are  
used for controlling and monitoring functions of the different on-chip units. Unused SFR  
addresses are reserved for future members of the XC2000 Family. Therefore, they  
should either not be accessed, or written with zeros, to ensure upward compatibility.  
In order to meet the needs of designs where more memory is required than is provided  
on chip, up to 12 Mbytes (approximately, see Table 3) of external RAM and/or ROM can  
be connected to the microcontroller. The External Bus Interface also provides access to  
external peripherals.  
Up to 768 Kbytes of on-chip Flash memory store code, constant data, and control  
data. The on-chip Flash memory consists of up to 3 modules with a maximum capacity  
of 256 Kbytes each. Each module is organized in 4-Kbyte sectors. One 4-Kbyte sector  
of Flash module 0 is used internally to store operation control parameters and protection  
information.  
Note: The actual size of the Flash memory depends on the chosen derivative (see  
Table 1).  
Each sector can be separately write protected1), erased and programmed (in blocks of  
128 Bytes). The complete Flash area can be read-protected. A user-defined password  
sequence temporarily unlocks protected areas. The Flash modules combine 128-bit  
read accesses with protected and efficient writing algorithms for programming and  
erasing. Dynamic error correction provides extremely high read data security for all read  
accesses. Accesses to different Flash modules can be executed in parallel.  
For timing characteristics, please refer to Section 4.4.2, for further Flash parameters,  
please refer to Section 5.3.  
1) To save control bits, sectors are clustered for protection purposes, they remain separate for  
programming/erasing.  
Data Sheet  
37  
V0.91, 2007-02  
Draft Version  
 复制成功!