内容描述: [The TLD7002-16ES is a 16 channel device with integrated and protected output stages. It is designed to control LEDs with a current up to 76.5 mA as linear current sink (LCS). The power stages can be configured in parallel for higher load currents. Each individual power output stage is configured to a 6-bit current set value stored in the OTP. 16 independent and individual PWM configurations can be set. A high-speed lighting interface is used for device OTP programming, configuration, control and]
分类和应用:
文件页数/大小: 82 页 / 3105 K
品牌: INFINEON [ Infineon ]
 浏览型号TLD7002-16ES的Datasheet PDF文件第66页浏览型号TLD7002-16ES的Datasheet PDF文件第67页浏览型号TLD7002-16ES的Datasheet PDF文件第68页浏览型号TLD7002-16ES的Datasheet PDF文件第69页浏览型号TLD7002-16ES的Datasheet PDF文件第71页浏览型号TLD7002-16ES的Datasheet PDF文件第72页浏览型号TLD7002-16ES的Datasheet PDF文件第73页浏览型号TLD7002-16ES的Datasheet PDF文件第74页  
TLD7002-16ES  
Datasheet  
9 Communication interface  
In case of an reset condition the MRC counter default value is set to 0.  
Figure 32  
Master rolling counter, function request and data length code byte  
9.1.11.12. StartADDR byte  
4
The start address byte is used for writing or reading up to 32 consecutive register locations starting from the defined  
start address register in a single command as shown in Figure 33. The number of successive write or read events is  
defined with the DLC.  
Table 39  
Start address byte overview  
Bits Type Description  
Field  
Start Address  
[7:0]  
w
Single byte start address for the 16-bit register write or read operation  
Figure 33  
Start address byte  
9.1.11.12. Data Word  
5
The two data bytes comprises the downloaded data from the master to the slave or the responded feedback from the  
slave to the master as shown in Figure 34.  
Table 40  
Data word - word structure overview  
Bits Type Description  
Field  
Data  
[15:8] w/r  
Data  
Contains the MSB(byte) of the data to written to the slave or read from the  
master  
Data  
[7:0] w/r  
Data  
Contains the LSB(byte) of the data to written to the slave or read from the  
master  
Datasheet  
70  
Rev.1.00  
2022-05-03  
 复制成功!