BTS7040-1EPA
PROFET™ +2 12V
Protection
Table 16 Electrical Characteristics: Protection - PROFET™ (continued)
Parameter
Symbol
Values
Typ.
70
Unit Note or
Test Condition
Number
Min.
Max.
1)
Auto Retry Time after Fault tRETRY
Condition
40
100
ms
ms
µs
P_8.6.1.5
See Figure 27 and
Figure 28
1)
Counter Reset Delay Time
after Fault Condition
tDELAY(CR)
40
50
70
100
150
P_8.6.1.6
P_8.6.1.7
See Figure 27 and
Figure 28
2)
Minimum DEN Pulse
tDEN(CR)
100
Duration for Counter Reset
See Figure 30
1) Functional test only.
2) Not subject to production test - specified by design.
8.7
Electrical Characteristics Protection - Power Output Stages
VS = 6 V to 18 V, TJ = -40 °C to +150 °C
Typical values: VS = 13.5 V, TJ = 25 °C
Typical resistive load connected to the output for testing (unless otherwise specified):
RL = 3.3 Ω
8.7.1
Protection Power Output Stage - 40 mΩ
Table 17 Electrical Characteristics: Protection - 40 mΩ
Parameter
Symbol
Values
Typ.
47
Unit Note or
Test Condition
Number
Min.
Max.
1)
Overload Detection Current IL(OVL0)_-40
at TJ = -40 °C
42
52
A
A
A
P_8.7.6.1
TJ = -40 °C
dI/dt = 0.2 A/µs
see Figure 24 and
Figure 25
2)
Overload Detection Current IL(OVL0)_25
at TJ = 25 °C
40
34
46
39
52
45
P_8.7.6.7
P_8.7.6.8
TJ = 25 °C
dI/dt = 0.2 A/µs
see Figure 24 and
Figure 25
2)
Overload Detection Current IL(OVL0)_150
at TJ = 150 °C
TJ = 150 °C
dI/dt = 0.2 A/µs
see Figure 24 and
Figure 25
Data Sheet
40
Rev. 1.10
2020-12-14