ELECTRICAL CHARACTERISTICS
Operating conditions: VCC = VDD = 3 ... 5.5 V, VBy = 12 ... 36 V, GNDA = GNDD = 0 V, RSET = 10 kΩ ±1% . All inputs on defined logic
states (high or low), Tj = -40 ... 125 °C unless otherwise stated. Functionality and parameters beyond operating conditions (for example
w.r. to independent voltage supplies) are to be verified within the individual application by FMEA methods.
Item Symbol
No.
Parameter
Conditions
Unit
Min.
Typ.
Max.
17
108 SR()lo
109 tplh()
Slew Rate lo
CL = 0 ... 100 pF, I(IOx) = -150mA
5
V/µs
µs
Propagation Delay until IOx: lo → V(IOx) > V0(IOx) + 1 V
6
hi
110 tphl()
Propagation Delay until IOx = off V(IOx) < 80 % (VBy - Vs(IOx)hi)
6
µs
I/O Stages: Current Sources at IO1...16
201 Ipd()
Pull-down Current Source
(200 µA)
V(IOx) = 3 V .. VBy;
V(IOx) = 3 V .. VBy;
160
510
200
600
240
690
µA
µA
202 Ipd()
Pull-down Current Source
(600 µA)
203 Ipd()
204 Ipu()
205 Ipu()
206 Ipu()
207 tp()Ion
Pull-down Current Source (2 mA) V(IOx) = 3 V .. VBy;
1.6
150
510
1.6
2
2.4
250
690
2.4
5
mA
µA
µA
mA
µs
Pull-up Current Source (200 µA) IOx = off, V(IOx) = 0 V .. VBy - 3 V
Pull-up Current Source (600 µA) IOx = off, V(IOx) = 0 V .. VBy - 3 V
200
600
2
Pull-up Current Source (2 mA)
IOx = off, V(IOx) = 0 V ..VBy - 3 V
Turn-on Time
Current Source aktiv
I(IOx) > 90 % Ipd(IOx) resp.
I(IOx) > 90 %Ipu(IOx)
208 tp()Ioff
209 Ifu()
Turn-off Time
Current Source inaktiv
I(IOx) < 10 % Ipd(IOx) resp.
I(IOx) < 10 % Ipu(IOx)
5
µs
Leakage Current
IOx with Input Function or
-50
70
µA
Output Function with IOx = off; VBy = 30 V
IL2 = IH2 = IL1 = IH1 = IL0 = IH0 = 0,
V(IOx) = 0V .. VBy
210 Irb()
211 Irb()
Leakage Current
Leakage Current
Conditions see Item-No. 209;
V(IOx) = -10 V .. 0 V, VBy = 30 V
-1.5
mA
µA
Conditions see Item-No. 209; only Input Func-
tion
V(IOx) = VBy ... VBy + 0.3 V
250
1
212 Irb()
213 Irb()
Leakage Current
Leakage Current
Conditions see Item-No. 209; only Input Func-
tion
V(IOx) = VBy + 0.3V ... VBy + 2V
mA
mA
no supply voltages VBy
V(IO)max = 36V
5
I/O Stages: Comparator IO 1..16
301 Vt()hi
302 Vt()lo
303 Vt()hys
304 Vt()hi
Threshold voltage hi
IOx with input function
82
%VCC
%VCC
mV
Threshold voltage lo
Hysteresis
IOx with input function
66
100
5.0
IOx with input function, Vt()hys = Vt()hi - Vt()lo
Threshold voltage hi referenced IOx with output function, Vt()hi = VBy - V(IOx)
to VBy
V
305 Vt()lo
Threshold voltage lo referenced IOx with output function, Vt()lo = VBy - V(IOx)
to VBy
6.7
20
V
306 Vt()hys
Hysteresis
IOx with output function, Vt()hys = Vt()lo - Vt()hi
I/O-Filter inaktive
100
120
mV
µs
307 tp(IOx-Dx) Propagation Delay Input IOx to
Data Output Dx
Thermal Shutdown
401 Toff1
Overtemperatur threshold level 1:
warning
145
°C
402 Ton1
403 Thys1
404 Toff2
Level 1 Release
115
2
140
7
°C
°C
°C
Level 1 Hysteresis
Thys1 = Toff1 - Ton1
Thys2 = Toff2 - Ton2
Overtemperatur threshold level 2:
shutdown
140
165
405 Ton2
406 Thys2
407 ∆T
Level 2 Release
120
13
145
35
°C
°C
°C
Level 2 Hysteresis
Temperature Difference Level 2 ∆T = Toff2 - Toff1
13
35
to Level 1