欢迎访问ic37.com |
会员登录 免费注册
发布采购

IBM25PPC750GXECB5H83T 参数 Datasheet PDF下载

IBM25PPC750GXECB5H83T图片预览
型号: IBM25PPC750GXECB5H83T
PDF下载: 下载PDF文件 查看货源
内容描述: [RISC Microprocessor, 32-Bit, 933MHz, CMOS, CBGA292, 21 X 21 MM, 1 MM PITCH, CERAMIC, BGA-292]
分类和应用: 时钟外围集成电路
文件页数/大小: 74 页 / 1054 K
品牌: IBM [ IBM ]
 浏览型号IBM25PPC750GXECB5H83T的Datasheet PDF文件第59页浏览型号IBM25PPC750GXECB5H83T的Datasheet PDF文件第60页浏览型号IBM25PPC750GXECB5H83T的Datasheet PDF文件第61页浏览型号IBM25PPC750GXECB5H83T的Datasheet PDF文件第62页浏览型号IBM25PPC750GXECB5H83T的Datasheet PDF文件第64页浏览型号IBM25PPC750GXECB5H83T的Datasheet PDF文件第65页浏览型号IBM25PPC750GXECB5H83T的Datasheet PDF文件第66页浏览型号IBM25PPC750GXECB5H83T的Datasheet PDF文件第67页  
Datasheet  
IBM PowerPC 750GX RISC Microprocessor  
DD1.X  
Table 5-8. 750GX Heat-Sink Vendors  
Company Names and Addresses for Heat-Sink Vendors  
Chip Coolers, Inc.  
333 Strawberry Field Rd.  
Warwick, RI 02886  
(800) 227-0254  
http://www.chipcoolers.com  
International Electronic Research Corporation (IERC)  
413 North Moss Street  
Burbank, CA 91502  
(818) 842-7277  
http://www.ctscorp.com/  
Aavid Thermalloy  
80 Commercial Street  
Concord, NH 03301  
(603) 224-9888  
http://www.aavid.com  
http://www.aavidthermalloy.com  
Wakefield Thermal Solutions Inc.  
33 Bridge Street  
Pellham, NH 03076  
(603) 635-2800  
http://www.wakefield.com  
5.7.1 Thermal Assist Unit  
IBM recommends that the thermal assist unit (TAU) in these devices be calibrated before use. Calibration  
methods are discussed in the IBM application note, Calibrating the Thermal Assist Unit in the  
IBM25PPC750L Processors. Although this note was written for the 750L, the calibration methods discussed  
in this document also apply to the 750GX.  
5.7.2 Minimum Heat Sink Requirements  
The worst-case power dissipation (PD) for the 750GX is shown in Table 3-5, Power Consumption for DD1.1,  
on page 17. A conservative thermal management design will provide sufficient cooling to maintain the junc-  
tion temperature (TJ) of the 750GX below 105°C at maximum PD and worst-case ambient temperature and  
airflow conditions.  
Many factors affect the 750GX power dissipation, including VDD, TJ, core frequency, process factors, and the  
code that is running on the processor. In general, PD increases with increases in TJ, VDD, core frequency,  
process variables, and the number of instructions executed per second.  
For various reasons, a designer may determine that the power dissipation of the 750GX in their application  
will be less than the maximum value shown in this datasheet. Assuming a lower PD will result in a thermal  
management system with less cooling capacity than would be required for the maximum PD shown in the  
datasheet. In this case, the designer may decide to determine the actual maximum 750GX PD in the partic-  
ular application. Contact your IBM PowerPC field applications engineer for more information.  
In addition to the system factors that must be considered in a cooling system analysis, three things should be  
noted.  
750GX_ds_body.fm SA14-2765-02  
September 2, 2005  
System Design Information  
Page 63 of 73  
 复制成功!