GS9090 Data Sheet  
If the received video format does not correspond to 525 or 625 digital component  
video standards as determined by the flywheel pixel and line counters, then one of  
two schemes for determining the EDH calculation ranges will be employed:  
1. Ranges will be based on the line and pixel ranges programmed by the host  
interface; or  
2. In the absence of user-programmed calculation ranges, ranges will be  
determined from the received TRS timing information.  
The registers available to the host interface for programming EDH calculation  
ranges include active picture and full field line/pixel start and end positions for both  
fields. Table 3-13 shows the relevant registers, which default to '0' after a device  
reset.  
If any or all of these register values are zero, then the EDH CRC calculation ranges  
will be determined from the flywheel generated timing. The first active and full field  
pixel will always be the first pixel after the SAV TRS code word. The last active and  
full field pixel will always be the last pixel before the start of the EAV TRS code  
words.  
Table 3-13: Host Interface Description for EDH Calculation Range Registers  
Register Name  
Bit  
Name  
Description  
R/W  
Default  
AP_LINE_START_F0  
Address: 15h  
15-11  
10-0  
Not Used  
0
AP_LINE_START_F0[10:0]  
Field 0 Active Picture start line data used  
to set EDH calculation range outside of  
SMPTE RP 165 values.  
R/W  
AP_LINE_END_F0  
Address: 16h  
15-11  
10-0  
Not Used  
0
AP_LINE_END_F0[10:0]  
Field 0 Active Picture end line data used  
to set EDH calculation range outside of  
SMPTE RP 165 values.  
R/W  
AP_LINE_START_F1  
Address: 17h  
15-11  
10-0  
Not Used  
0
AP_LINE_START_F1[10:0]  
Field 1 Active Picture start line data used  
to set EDH calculation range outside of  
SMPTE RP 165 values.  
R/W  
AP_LINE_END_F1  
Address: 18h  
15-11  
10-0  
Not Used  
0
AP_LINE_END_F1[10:0]  
Field 1 Active Picture end line data used  
to set EDH calculation range outside of  
SMPTE RP 165 values.  
R/W  
FF_LINE_START_F0  
Address: 19h  
15-11  
10-0  
Not Used  
0
FF_LINE_START_F0[10:0]  
Field 0 Full Field start line data used to  
set EDH calculation range outside of  
SMPTE RP 165 values.  
R/W  
FF_LINE_END_F0  
Address: 1Ah  
15-11  
10-0  
Not Used  
0
FF_LINE_END_F0[10:0]  
Field 0 Full Field end line data used to  
set EDH calculation range outside of  
SMPTE RP 165 values.  
R/W  
28201 - 1 July 2005  
41 of 70  
 复制成功!