ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 4. Static Electrical Characteristics
Characteristics noted under conditions 4.5 V
≤
V
DD
≤
5.5 V, 9.0 V
≤
V
PWR
≤
16 V, -40°C
≤
T
A
≤
125°C, unless otherwise noted.
Typical values noted reflect the approximate value with V
BAT
= 13 V, T
A
= 25°C.
Characteristic
POWER INPUT
Supply Voltage Range
Quasi-Functional
Fully Operational
Supply Current (All Outputs ON, I
OUT
= 0.5 A)
Sleep State Supply Current at
RST
≤
0.2 V
DD
and/or V
DD
< 0.5 V
Sleep State Output Leakage Current (Per Output,
RST
= 0 V)
Overvoltage Shutdown
Overvoltage Shutdown Hysteresis
Logic Supply Voltage
Logic Supply Current
RST
≥
0.7 V
DD
RST
≤
0.5 V
Symbol
Min
Typ
Max
Unit
V
V
PWR(QF)
V
PWR(FO)
V
PWR(ON)
I
PWR(ON)
I
PWR(SS)
V
OV
V
OV(HYS)
V
DD
I
DD
–
–
V
DD
(UVLO)
2.5
1.0
–
–
4.0
25
3.5
mA
5.5
9.0
–
–
–
28
0.2
4.5
–
–
1.0
1.0
1.0
32
0.8
–
9.0
26.5
2.0
2.5
2.5
36
1.5
5.5
mA
µ
A
µ
A
V
V
V
µ
A
V
Logic Supply Undervoltage Lockout Threshold
POWER OUTPUT
Drain-to-Source ON Resistance (I
OUT
= 0.5 A, T
J
- 25
°
C)
V
PWR
= 5.5 V
V
PWR
= 9.0 V
V
PWR
= 13 V
Drain-to-Source ON Resistance (I
OUT
= 0.5 A, T
J
- 150
°
C)
V
PWR
= 5.5 V
V
PWR
= 9.0 V
V
PWR
= 13 V
Output Self-Limiting Current
Outputs Programmed ON, V
OUT
= 0.6 V
DD
Output Fault Detect Threshold
Output Programmed OFF
RDS(ON)
Ω
–
–
–
–
0.6
0.55
2.0
1.2
1.0
Ω
–
–
–
–
1.2
1.0
3.0
1.6
1.2
A
1.0
2.0
3.0
V
2.5
3.0
3.5
RDS(ON)
I
OUT(LIM)
V
OUTth(F)
Notes
16. SPI inputs and outputs operational. Fault status reporting may not be fully operational within this voltage range. Outputs remain
operational somewhat below this V
PWR
range, but R
DS(ON)
will increase, causing power dissipation to increase. Outputs will re-
establish their instructed state following a V
PWR
interruption as long as V
DD
remains non-interrupted.
17.
18.
19.
20.
This parameter is guaranteed by design, but it is not production tested.
Measured with the
RST
pin held at a logic high state. Outputs can be OFF or ON or in any combination thereof.
Device incorporates a power-ON reset function. For V
DD
less than the Undervoltage Lockout Threshold voltage, all data registers are
reset and all outputs are disabled.
Output Fault Detect Threshold with outputs programmed OFF. Output fault detect thresholds are the same for output opens and shorts.
33291
6
Analog Integrated Circuit Device Data
Freescale Semiconductor