Feature Integration Technology Inc.
Fintek
F75373
0
F_FAULT_LEVE
L
R/W
When set this bit to 0 fan fault is low active (default). if set to 1 fan
fault is high active
6.4
Configuration Register Index 03h
Power on default <7:0> = 00h
Bit
Name
Attribute
Description
7
PIN6_MODE
R/W
00: pin6 function is GPIO3
01: pin6 is used as OVT
10: pin6 is used as Voltage fault function
11: Reserved
5
OVT_LEVEL
R/W
R/W
When set this bit to 0 OVT is low active (default), else if set to 1 OVT
is high active
3-4 OVT_QUEUE
OVT queue is use to filter the temperature noise, it define the times of
the event when OVT is asserted.
00: 1 times
01: 3 times
10: 5 times
11: 7 times
2
V_FAULT_LEVE
L
R/W
R/W
Voltage fault level. When set this bit to 0 voltage fault is low active
(default). if set to 1 fan fault is high active
1-0 V_FAULT_QUE
UE
Voltage fault queue. It is used to filter the voltage noise, the follow
define the times of the event when VOLT_FAULT is asserted.
00: 1 times
01: 3 times
10: 5 times
11: 7 times
6.5
Serial Bus Address Register Index 04h
Power on default: 5Ah or 5Ch.
Bit
Name
Attribute
Description
15
V0.25P