F75373  
6.2  
Configuration Register Index 01h  
Power on default <7:0> = 00h  
Bit  
7-2  
1
Name  
Attribute  
RO  
Description  
Reserved  
Read back will be 0  
PIN4_MODE  
R/W  
Pin 4 mode select, set this bit to 1 will enable PWMOUT2 output, else  
if set this bit to 0, pin 4 will be enable the GPIO1 function.(default)  
This mode is trappable: When PIN3 trapped to high at power-on,  
PIN4 is set to PWMOUT2. When PIN3 trapped to low at power-on,  
PIN4 is set to GPIO1.  
0
PIN2_MODE  
R/W  
Pin 2 mode select, set this bit to 1 will enable FANIN2 input, if set this  
bit to 0 pin 2 will be enable the GPIO0 function.(default).  
This mode is trappable: When PIN3 trapped to high at power-on,  
PIN2 is set to FANIN2. When PIN3 trapped to low at power-on, PIN2  
is set to GPIO0.  
6.3  
Configuration Register Index 02h  
Power on default <7:0> = 00h  
Bit  
Name  
Attribute  
Description  
00: pin5 function is GPIO2  
7-6  
PIN5_MODE  
R/W  
01: pin5 is used as SMI  
10: pin5 is used as Fan fault function  
11: LED out(1Hz/0.5Hz select by bit2)  
If set to 0, SMI will be level mode else if this bit set to 1, SMI will be  
pulse mode.  
5
4
SMI_MODE  
SMI_LEVEL  
R/W  
R/W  
When set this bit to 0 SMI is low active (default). if set to 1 SMI is high  
active  
3
2
Reserved  
R/W  
R/W  
Reserved register  
LED_FREQ  
When set this bit to 1 fan fault LED output frequency will be 0.5HZ,  
else is 1Hz(default)  
1
F_FAULT_MOD  
E
R/W  
When set this bit to 0 the fan fault will be level mod, else if set to 1 the fan  
fault will indicate by LED function(1Hz or 0.5Hz) the LED frequency can  
set by REG02H bit2  
14  
V0.25P  