CMS4A16LAx–75Ex
Maximum Ratings
*Stresses greater than those listed under “Maximum Ratings”
may cause permanent damage to the device.This is a stress
rating only, and functional operation of the device at these or
any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to abso-
lute maximum rating conditions for extended periods may affect
reliability.
Voltage on VDD/VDDQ Supply
Relative to VSS…….. …….………………………...-0.5V to + 3.6V
Voltage on Inputs, NC or I/O Pins
Relative to VSS……... …….…………………….…. –0.5V to +3.6V
Storage Temperature(plastic) ………….………. -55℃ to + 150℃
Power Dissipation ………………………….….………………1W
Operating Range
Device
Range
Special
Ambient Temperature
-10℃ to +60℃
0℃ to +70℃
VDD
VDDQ
CMS4A16LAx-xxES
CMS4A16LAx-xxEC
CMS4A16LAx-xxEE
CMS4A16LAx-xxEI
Commercial
Extended
Industrial
1.7V to 1.95V
1.7V to VDD
-25℃ to +85℃
-40℃ to +85℃
DC ELECTRICAL CHARACTERISTICS AND OPERATING CONDITIONS[21.22.]
Parameter / Condition
Symbol
Min
Max
Units
Supply Voltage
VDD
VDDQ
VIH
1.7
1.7
1.95
1.95
V
V
V
V
V
V
I/O Supply Voltage
Input High Voltage : Logic 1 All Inputs [23.]
0.8* VDDQ
-0.3
VDDQ +0.3
0.3
Input Low Voltage : Logic 0 All Inputs [23.]
VIL
Data Output High Voltage : Logic 1 : All Inputs(-0.1mA)
Data Output Low Voltage : Logic 0 : All Inputs(0.1mA)
VOH
VOL
0.9* VDDQ
0.2
5
Input Leakage Current :
Any Input 0V=VIN=VDD (All other pins not under test=0V)
II
-5
-5
㎂
㎂
Output Leakage Current : DQs are disabled ; 0V= VOUT=VDDQ
lOZ
5
Table 7. AC OPERATING CONDITIONS[21.22.23.24.25.26.]
Parameter / Condition
Input High Voltage : Logic 1 All Inputs
Symbol
VIH
Value
Units
0.9* VDDQ
0.2
V
V
V
Input Low Voltage : Logic 0 All Inputs
VIL
Input and Output Measurement Reference Level
0.5*VDDQ
15
Rev. 0.5, May. ‘07