 浏览型号EDD51323DBH-6ELS-F的Datasheet PDF文件第2页浏览型号EDD51323DBH-6ELS-F的Datasheet PDF文件第3页浏览型号EDD51323DBH-6ELS-F的Datasheet PDF文件第4页浏览型号EDD51323DBH-6ELS-F的Datasheet PDF文件第5页浏览型号EDD51323DBH-6ELS-F的Datasheet PDF文件第7页浏览型号EDD51323DBH-6ELS-F的Datasheet PDF文件第8页浏览型号EDD51323DBH-6ELS-F的Datasheet PDF文件第9页浏览型号EDD51323DBH-6ELS-F的Datasheet PDF文件第10页  
EDD51323DBH-LS  
DC Characteristics 1 (TA = 25°C to +85°C, VDD and VDDQ = 1.7V to 1.95V, VSS and VSSQ = 0V)  
Parameter  
Symbol  
Grade  
max.  
Unit  
Test condition  
Notes  
One bank active-precharge,  
CKE = H, /CS = H between valid commands,  
tCK = tCK (min.), tRC = tRC (min.),  
Address bus inputs are SWITCHING;  
Data bus inputs are STABLE  
Operating current  
(ACT-PRE)  
-5BLS  
-6ELS  
90  
65  
IDD0  
mA  
All banks idle,  
CKE = L, /CS = H, tCK = tCK (min.),  
Address and control inputs are SWITCHING;  
Data bus inputs are STABLE  
Standby current in power-down IDD2P  
0.8  
0.6  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
All banks idle,  
CKE = L, /CS = H, CK = L, /CK = H,  
Address and control inputs are SWITCHING;  
Data bus inputs are STABLE  
Standby current in power-down  
IDD2PS  
with clock stop  
All banks idle,  
CKE = H, /CS = H, tCK = tCK (min.),  
Address and control inputs are SWITCHING;  
Data bus inputs are STABLE  
Standby current in  
IDD2N  
-5BLS  
-6ELS  
6.0  
5.0  
non power-down  
All banks idle,  
CKE = H, /CS = H, CK = L, /CK = H,  
Address and control inputs are SWITCHING;  
Data bus inputs are STABLE  
Standby current in non power-  
IDD2NS  
2.0  
3.0  
2.0  
10  
down with clock stop  
One bank active,  
CKE = L, /CS = H, tCK = tCK (min.),  
Address and control inputs are SWITCHING;  
Data bus inputs are STABLE  
Active standby current in  
IDD3P  
power-down  
One bank active,  
CKE = L, /CS = H, CK = L, /CK = H;  
Address and control inputs are SWITCHING;  
Data bus inputs are STABLE  
Active standby current in  
IDD3PS  
power-down with clock stop  
One bank active,  
CKE = H, /CS = H, tCK = tCK (min.),  
Address and control inputs are SWITCHING;  
Data bus inputs are STABLE  
Active standby current in non  
IDD3N  
power-down  
One bank active,  
CKE = H, /CS = H, CK = L, /CK = H,  
Address and control inputs are SWITCHING;  
Data bus inputs are STABLE  
Active standby current in non  
IDD3NS  
7.0  
power-down with clock stop  
One bank active,  
Continuous burst reads or writes;  
tCK = tCK (min.), CL = 3, BL = 4, IOUT = 0mA,  
Address inputs are SWITCHING,  
50% data change each burst transfer  
CKE = H, tCK = tCK (min.), tRFC = tRFC (min.),  
Address and control inputs are SWITCHING;  
Data bus inputs are STABLE  
-5BLS  
-6ELS  
155  
130  
Burst operating current  
Auto-refresh current  
IDD4  
mA  
IDD5  
IDD8  
106  
10  
mA  
Address and control inputs are STABLE;  
Data bus inputs are STABLE  
Deep power-down  
current  
µA  
Preliminary Data Sheet E1432E20 (Ver. 2.0)  