BNCꢀSeries
Unit:mm
○Assembly Instruction(1)
Parts Configulration
MIL Clamp
Gasket
Gasket
Clamp
Nut
Washer
Clamp
Male Contact
Plug Body
Female Contact
Jack Body
Cut the cable as fig.1.
①
A
ꢀ Please be carefule to not damage the outer
conductor.
①
Applicable Cable
A
5D-2V, RG-59/U, RG-62/U 10mm
Washer
Nut
Gasket
Clamp
3D-2V, 5D-2W
15mm
RG-55/U, RG-58/U
3D-2W
12mm
②
③
Insert the nut, washer, gasket and clamp.
②
● The clamp is located on the outer conductor of the
ꢀ cable. Pick the outer conductor.
Cut the insulator and center conductor as fig.3.
③
ꢀFold up the outer conductor to the clamp equally and
cut the outer conductor of the cable along the clamp
as fig.3.
C
●Please be careful to not damage the center conductor.
B
Applicable Cable
B
C
3D-2V, 3D-2W,
RG-55/U, RG-58/U
5D-2V
6mm
3mm
Soldering
Contact
No Gap
7mm
5mm
④
⑤
RG-59/U, RG-62/U
5D-2W
5.5mm 3mm
7.2mm 5.4mm
Solder up the contact to the center conductor.
④
● Please be careful to not be swelled up the solder.
● Please be careful to not gap between contact and
insulator.
● Please be careful to not deform the insulator by
soldering
Body
Cable assembly
Insert the body into the above cable assembly and
screw up the nut.
⑤
● Please screw up the nut by wrench tightly.
Applicable Cable Recommended Tightening Torque
Hex Dia:. 9.5
Dia:. 9.5
3D-2V, RG-55/U, RG-58/U
RG-59/U, RG-62/U, 3D-2W
5D-2V
117.6 〜 147N・cm(12 〜 15kgf・cm)
196N・cm(20kgf・cm)
441N・cm(45kgf・cm)
5D-2W
490 〜 686N・cm(50 〜 70kgf・cm)
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
9