ES51967
6,600 Counts Auto DMM
3.6 Relative + Max/Min + HOLD
Max/Min mode can be nested in REL mode. The meter displays the maximum or
minimum value relative to the reference when Max/Min is pressed in REL mode.
Pressing HOLD under REL + Max/Min makes the meter stop updating the LCD panel.
Original State
(Auto/Manual)
Push REL
Push REL
〝REL〞active.
The relative value
Push Max/Min > 1s
Push Max/Min
〝REL〞and〝Max〞active.
〝REL〞and〝Min〞active.
〝REL〞〝Max〞〝Min〞
Maximum rel. value
Minimum rel. value
blink. Current rel. value
Push Max/Min
Push Max/Min
Push HOLD
Push HOLD
Push HOLD
〝REL〞,〝Max〞,
〝H〞active. Hold
max. rel. value
〝REL〞, 〝Min〞,
〝H〞active. Hold
〝REL〞〝, Max〞〝, Min〞,
〝H〞blink. Hold the
current rel. value
Push Max/Min
Push Max/Min
min. rel. value
Push Max/Min
3.7 ZERO function
In manual DC 6.600A, 66.00A, 660.0A and 6600A, auto DC 66.00A/660.0A and auto
DC 660.0A/6600A mesurement modes, ES51967 provides Zero function to remove the
residual current value. Push ZERO bottom less than one second to enter Zero mode. In
Zero mode, the LCD panel displays DN+K - DN, where N = 1, 2, 3, … , DN is the last
conversion value before Zero is pushed, and DN+K is the current conversion value. If
Zero is pushed again in Zero mode, the meter will refresh the DN value and displays the
DN+K - DN again. The meter returns to normal operation if Zero is pressed and held for
longer than one second. Pressing HOLD in Zero mode makes the meter stop updating
the LCD panel. In 2-range auto DCA modes for clampmeter (660.0A/6600A or
66.00A/660.0A), the system will stay in automatic mode, even if the Zero function is
activated. In other words, It could achieve real automatic operation. In automatic mode,
Zero function could not be entered from higher range, but it could be still activated if
current range is lower one. This is because most residual current value is so small that
the range could not be higher one in automatic mode. When enter Zero mode from
V2.6
19
08/10/06