ES51967
6,600 Counts Auto DMM
4.3 DIGIT 3 – DIGIT 0
Digit 3 is the most significant digit on the LCD panel, and digit 0 is the least significant
digit.
Digit
Code
0
1
2
3
4
5
6
7
8
9
0110000
0110001
0110010
0110011
0110100
0110101
0110110
0110111
0111000
0111001
Note: Because the cycle time of measurement for continuity/diode mode is only 82.5ms,
the least significant digit may not be accurate
4.4 STATUS
The format of this package shown below. In Temperature mode, judge is 1 if the unit is
°C and is 0 if the unit is °F. Sign field indicates whether the minus sign on the LCD
panel is on or off. BATT field is one when battery low condition is true. OL indicates
input overflow. In VAHz mode, the judge is 1 if the duty cycle mode is active.
0
1
1
Judge
BIT 3
Sign
BIT 2
BATT
BIT1
OL
BIT 0
BIT6
BIT 5
BIT 4
4.5 OPTION 1
0
1
1
UL
BIT 3
VASEL VBAR
BIT 2 BIT1
0
BIT 6
BIT 5
BIT 4
BIT 0
The UL bit will be 1 only in following conditions:
1. The reading is less than 10.0Hz(LCD shows UL) in FR1 range of frequency mode.
2. The input frequency is less than 10.0Hz or the duty cycle value is less than 10.0% in
duty cycle measurement mode.
The VASEL bit will be 1, when the VASEL pin is connected to V-.
The VBAR bit will be 1, when the VBAR pin is connected to V-.
V2.6
23