ES51967
6,600 Counts Auto DMM
When FC5 is low, the measurement mode list is below.
SLACDC FC1
FC2
0
1
1
0
1
1
0
0
0
0
0
1
0
1
1
0
1
1
0
1
0
0
0
0
0
1
0
1
1
1
FC3
1
0
1
0
1
0
0
1
0
1
0
1
1
1
0
1
0
1
0
0
0
1
0
1
0
1
1
1
0
0
FC4
1
1
1
0
0
0
0
0
1
1
1
1
0
0
0
1
1
1
0
0
0
0
1
1
1
1
0
0
0
1
Mode
DC Voltage Measurement
123Auto DC Current Measurement(µA)
123Auto DC Current Measurement(mA)
166A DC Current Measurement(A)
Duty Cycle Measurement
2Manual DC 6.600A
0
0
0
0
X
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
X
1
1
1
0
1
1
1
1
1
0
0
0
0
0
0
1
1
1
0
1
1
1
1
0
0
0
0
0
0
0
2Manual DC 66.00A
2Manual DC 660.0A
2Manual DC 6600A
Resistance Measurement
Continuity Check
Diode Measurement
Frequency Measurement
Capacitance Measurement
Temperature Measurement (℃)
AC Voltage Measurement
123Auto AC Current Measurement(µA)
123Auto AC Current Measurement(mA)
166A AC Current Measurement(A)
2Manual AC 6.600A
2Manual AC 66.00A
2Manual AC 660.0A
2Manual AC 6600A
*ADP0
*ADP1
*ADP2
*ADP3
Capacitance Measurement (Clamp)
Temperature Measurement (℉)
Resistance Measurement
X means “don’t care”.
*When FC5 is low, the ADP0, ADP1, ADP2 and ADP3 modes can NOT display minus sign.
1These modes could be designed for multimeter current modes, please refer to section 1.3.
2These modes could be designed for clampmeter current modes, please refer to section 1.4.
3These modes could be designed for clampmeter 2-range automatic voltage modes, please refer to
section 1.5.
V2.6
15
08/10/06