BMA253
Data sheet
Page 66
Register 0x14 (BGW_SOFTRESET)
Controls user triggered reset of the sensor.
Name
Bit
0x14
7
BGW_SOFTRESET
6
5
4
Read/Write
Reset
W
0
W
0
W
0
W
0
Value
Content
softreset
Bit
3
2
1
0
Read/Write
Reset
W
0
W
0
W
0
W
0
Value
Content
softreset
softreset:
0xB6 triggers a reset. Other values are ignored. Following a delay, all
user configuration settings are overwritten with their default state or the
setting stored in the NVM, wherever applicable. This register is functional in
all operation modes. Please note that all application specific settings which
are not equal to the default settings (refer to 6.2 register map), must be
reconfigured to their designated values.
Register 0x16 (INT_EN_0)
Controls which interrupt engines in group 0 are enabled.
Name
Bit
0x16
7
INT_EN_0
6
5
4
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
flat_en
3
orient_en
s_tap_en
d_tap_en
Bit
2
1
0
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
reserved
slope_en_z
slope_en_y
slope_en_x
flat_en:
flat interrupt: ‘0’disabled, or ‘1’ enabled
orientation interrupt: ‘0’disabled, or ‘1’ enabled
single tap interrupt: ‘0’disabled, or ‘1’ enabled
double tap interrupt: ‘0’disabled, or ‘1’ enabled
write ‘0’
orient_en:
s_tap_en:
d_tap_en
reserved:
slope_en_z:
slope_en_y:
slope_en_x:
slope interrupt, z-axis component: ‘0’disabled, or ‘1’ enabled
slope interrupt, y-axis component: ‘0’disabled, or ‘1’ enabled
slope interrupt, x-axis component: ‘0’disabled, or ‘1’ enabled
BST-BMA253-DS000-01 | Revision 1.0 | August 2015
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.