BMA253
Data sheet
Page 62
Register 0x0F (PMU_RANGE)
The register allows the selection of the accelerometer g-range.
Name
Bit
0x0F
7
PMU_RANGE
6
5
4
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
reserved
3
0
Bit
2
1
0
Read/Write R/W
R/W
0
R/W
1
R/W
1
Reset
0
Value
Content
range<3:0>
range<3:0>:
reserved:
Selection of accelerometer g-range:
´0011b´ ±2g range; ´0101b´ ±4g range; ´1000b´ ±8g range;
´1100b´ ±16g range; all other settings reserved (do not use)
write ‘0’
Register 0x10 (PMU_BW)
The register allows the selection of the acceleration data filter bandwidth.
Name
Bit
0x10
7
PMU_BW
6
5
4
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
reserved
3
bw<4>
0
Bit
2
1
0
Read/Write R/W
R/W
1
R/W
1
R/W
1
Reset
1
Value
Content
bw<3:0>
bw<4:0>:
reserved:
Selection of data filter bandwidth:
´00xxxb´ 7.81 Hz, ´01000b´ 7.81 Hz, ´01001b´ 15.63 Hz,
´01010b´ 31.25 Hz, ´01011b´ 62.5 Hz, ´01100b´ 125 Hz,
´01101b´ 250 Hz,
´1xxxxb´ 1000 Hz
´01110b´ 500 Hz, ´01111b´ 1000 Hz,
write ‘0’
BST-BMA253-DS000-01 | Revision 1.0 | August 2015
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.