BMA253
Data sheet
Page 69
Register 0x19 (INT_MAP_0)
Controls which interrupt signals are mapped to the INT1 pin.
Name
Bit
0x19
7
INT_MAP_0
6
5
4
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
int1_flat
3
int1_orient
int1_s_tap
int1_d_tap
Bit
2
1
0
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
int1_slo_no_mot
int1_slope
int1_high
int1_low
int1_flat:
map flat interrupt to INT1 pin: ‘0’disabled, or ‘1’ enabled
map orientation interrupt to INT1 pin: ‘0’disabled, or ‘1’ enabled
map single tap interrupt to INT1 pin: ‘0’disabled, or ‘1’ enabled
map double tap interrupt to INT1 pin: ‘0’disabled, or ‘1’ enabled
int1_orient:
int1_s_tap:
int1_d_tap:
int1_slo_no_mot: map slow/no-motion interrupt to INT1 pin: ‘0’disabled, or ‘1’ enabled
int1_slope:
int1_high:
int1_low:
map slope interrupt to INT1 pin: ‘0’disabled, or ‘1’ enabled
map high-g to INT1 pin: ‘0’disabled, or ‘1’ enabled
map low-g to INT1 pin: ‘0’disabled, or ‘1’ enabled
BST-BMA253-DS000-01 | Revision 1.0 | August 2015
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.