BMA253
Data sheet
Page 68
Register 0x18 (INT_EN_2)
Controls which interrupt engines in group 2 are enabled.
Name
Bit
0x18
7
INT_EN_2
6
5
4
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
reserved
3
Bit
2
1
0
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
slo_no_mot_sel
slo_no_mot_en_z slo_no_mot_en_y slo_no_mot_en_x
reserved:
write ‘0’
slo_no_mot_sel: select ‘0’slow-motion, ‘1’ no-motion interrupt function
slo_no_mot_en_z: slow/n-motion interrupt, z-axis component: ‘0’disabled, or ‘1’ enabled
slo_no_mot_en_y: slow/n-motion interrupt, y-axis component: ‘0’disabled, or ‘1’ enabled
slo_no_mot_en_x:slow/n-motion interrupt, x-axis component: ‘0’disabled, or ‘1’ enabled
BST-BMA253-DS000-01 | Revision 1.0 | August 2015
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.