ATH10T05 Series —5-V Input
Typical Characteristics
10-A, 5-V Input Non-Isolated
Wide-Output Adjust Power Module
Characteristic Data; Vin =5 V (See Note A)
Safe Operating Area; Vin =5 V (See Note B)
Efficiency vs Load Current
Output Voltage =3.3 V
100
90
80
70
60
50
40
30
20
90
80
70
60
50
VOUT
3.3 V
2.5 V
2.0 V
1.8 V
1.5 V
1.0 V
Airflow
400LFM
200LFM
100LFM
Nat conv
0
2
4
6
8
10
0
2
4
6
8
10
Iout (A)
Iout - Amps
Output Ripple vs Load Current
Output Voltage =1.5 V
90
80
70
60
50
40
30
20
50
40
30
20
10
0
VOUT
Airflow
2.5
3.3
2.0
1.8
1.0
1.5
400LFM
200LFM
100LFM
Nat Conv
0
2
4
6
8
10
0
2
4
6
8
10
Iout (A)
Iout - Amps
Power Dissipation vs Load Current
3
2.5
2
1.5
1
0.5
0
0
2
4
6
8
10
Iout - Amps
The products listed hereunder are prototype or pre-production devices which have not been fully qualified to Astec’s
specifications. Product specifications are subject to change without notice. Astec makes no warranty, either expressed,
implied, or statutory, including implied warranty of merchantability or fitness for a specific purpose, of these products.
Note A: Characteristic data has been developed from actual products tested at 25°C. This data is considered typical data for the Converter.
Note B: SOA curves represent the conditions at which internal components are at or below the manufacturer’s maximum operating temperatures. Derating limits apply to
modules soldered directly to a 4-layer PCB with 1 oz. copper.
North America (USA): 1-888-41-ASTEC
Europe (UK): 44(1384)842-211
Asia (HK): 852-2437-9662