欢迎访问ic37.com |
会员登录 免费注册
发布采购

3196 参数 Datasheet PDF下载

3196图片预览
型号: 3196
PDF下载: 下载PDF文件 查看货源
内容描述: 电力质量分析仪 [POWER QUALITY ANALYZER]
分类和应用:
文件页数/大小: 12 页 / 1902 K
品牌: ASM-SENSOR [ ASM GMBH ]
 浏览型号3196的Datasheet PDF文件第4页浏览型号3196的Datasheet PDF文件第5页浏览型号3196的Datasheet PDF文件第6页浏览型号3196的Datasheet PDF文件第7页浏览型号3196的Datasheet PDF文件第8页浏览型号3196的Datasheet PDF文件第9页浏览型号3196的Datasheet PDF文件第11页浏览型号3196的Datasheet PDF文件第12页  
10  
(Items in blue symbolize specifications unique to Model 9624-10, and are not available in the standard Model 9624.)  
-10  
9624 / Specifications  
Demand calculation function  
-1. Function specifications  
Data loading functions  
Settings  
:
Analysis start time/period  
:
Set the year, month, day, hours, minutes,  
and seconds. /1 to 31 days  
Data that can be loaded  
:
Binary data recorded using the 3196  
SET files (Settings data), ITV files (TIME PLOT data)  
EVT files (Event data (lists, voltage and current waveforms,  
transient waveforms, numerical values), FLC files (Flicker  
Demand interval settings :5, 10, or 30 minutes, 1, 2, 3, 6, or 12 hours  
Display method and calculation items :  
,
Demand graph (for consumption only), Average demand (average demand value  
for the specified analysis period)  
,
Maximum demand (maximum demand value for the  
specified analysis period), Load ratio (average demand/maximum demand × 100 [%])  
data (∆V10, IEC)), TRN files (Transient waveforms),  
EN50160. files (EN50160 dasta),  
EVENT.EN files (EN50160 Event data)  
ITIC curve display function  
Display function  
: Plot event points on limited value curve (points indicating  
swell/dip/interruption occurrence period and voltage)  
Maximum data capacity  
:
Up to 528 MB  
Data display functions  
SYSTEM display function  
Screen display  
TIME PLOT display function  
Screen display  
Percent of nominal voltage: Maximum swell voltage or residual voltage ratio against  
official voltage  
:
:
SYSTEM (settings) content screen  
Violation count display  
Limit curve selection  
: Number of upper-limit violations, number of lower- limit  
violations, and total number of events  
: ITIC curve or user-defined curve (any setting)  
RMS fluctuation, voltage fluctuation, harmonic  
fluctuation, inter-harmonic fluctuation  
Up to 4 screens  
EN50160 display function  
Screen display  
Number of display screens  
Cursor function  
EVENT list display function  
Screen display  
Display method selection  
EVENT data display function  
Display function  
:
:
: Overview/Harmonic/Signaling/Measurement result sorting  
A and B cursors (interval calculation function provided)  
Copy function  
Copy content  
: Saves the various screens in BMP format  
:
:
EVENT list content display  
Order events occurred in, or order of priority  
Print function  
Print format: Prints screen images, Paper size: A4 and Letter, Print preview: Yes  
CSV format conversion function  
:
:
Display the event data selected in the EVENT list  
display screen  
Display one of the following screens ((1) to (4))  
Screens that can be converted  
Conversion settings  
:
:
TIME PLOT and event waveform screens  
Specified interval conversion (TIME PLOT screen only)  
Conversion setting selection (TIME PLOT screen only)  
Screen display  
(1)Waveform display :Select from the voltage/current waveform, 4-channel  
voltage waveform, 4-channel current waveform, and  
Report creation function  
voltage/transient overvoltage waveform displays.  
Select from the harmonic RMS value and phase angle  
Output format  
: Output setting contents can be printed, or saved as a rich text file.  
(2)Vector display  
(3)DMM display  
:
(1) Automatic output : RMS voltage fluctuation graph, worst case, maximum/minimum  
list, total harmonic voltage distortion graph, Overview and  
Signaling data of EN50160, and all event detail list.  
(2) Arbitrary output : Includes, in addition to automatic output, RMS current  
fluctuation graph, transient waveform, total harmonic current  
distortion graph, Harmonic and result classification data of the  
EN50160, and settings list.  
displays.  
:
Displays power, voltage, and current values.  
(4)Harmonics display:Select from the harmonics bar graph and list displays.  
Cursor function  
:
A and B cursors (interval calculation function provided)  
for the waveform display screen  
Positive/ Negative/ Zero phase calculation function  
:Display voltage and current of the positive phase, negative  
(3) Detailed output  
: Voltage fluctuation, RMS fluctuation, harmonics fluctuation, and  
phase, and zero phase.(In vector display screen, this is conducted  
during the 3P4W wiring analysis.)  
interharmonics fluctuation.  
Settings save function  
Flicker graph Display function  
Save user-defined curves, setting for sorting measurement result, report setting, etc.  
Screen display  
Cursor function  
:
:
∆V10 Flicker graph or IEC Flicker graph  
A and B cursors (interval calculation function provided)  
Download function  
Download data from the 3196 via LAN.  
EVENT voltage fluctuation graph Display function  
Cursor function A and B cursors (interval calculation function provided)  
:
-2. Basic specifications  
Integral power consumption calculation function  
Supplied accessories  
Operating environment  
OS  
:
:
:
CD-R × 1  
PC/AT-compatible devices  
Settings  
:
Analysis start time/period  
:
Set the year, month, day, hours, minutes,  
and seconds. /1 to 31 days  
English or Japanese versions of the following  
• Microsoft Windows 95 (9624 only, OSR2 or later versions  
only supported, Internet Explorer 3 or later required)  
• Microsoft Windows 98, Me, NT 4.0, 2000 or XP  
At least 128 MB  
Display method and calculation items :  
Integral power consumption graph, Integral power consumption (consumption +  
regeneration, and cursor measurement functions provided), Maximum integral power  
consumption (final integral power consumption for the specified analysis period)  
Memory  
:
3196 Specifications  
-1. Measurement and recording items  
-2. Basic specifications  
Power quality measurement  
standards conformance  
Power P&Harm ALL_D  
Power P&Harm ALL_D  
Recording item  
Transient overvoltage  
Voltage swell  
Recording item  
:
IEC61000-4-30:2002, IEEE1159,  
EN50160:1999  
Voltage unbalance factor  
Current unbalance factor  
Harmonic voltage  
Clock functions  
Real-time clock accuracy  
Internal memory capacity for data  
Maximum recording interval 1 month (internal memory)  
Manual/Specified time  
:
Auto calendar, auto leap year, 24-hour clock  
Within ±0.3 s/day (when the 3196 is turned on)  
13 MB (time series and event data)  
×
:
Voltage dip  
:
Instantaneous interruption  
Frequency  
Harmonic current  
:
×
×
×
×
×
Measurement time control  
Time series data settings  
:
Harmonic power  
RMS voltage  
Harmonic voltage-current phase difference  
Inter-harmonic voltage  
Inter-harmonic current  
Total harmonic voltage distortion factor  
Total harmonic current distortion factor  
Total inter-harmonic voltage distortion factor  
Total inter-harmonic current distortion factor  
K factor  
×
×
Recording item setting patterns  
MAX/MIN/AVE values  
:
:
Power, P&Harm, and ALL DATA  
AVE values, ALL values (maximum,  
minimum, and average values)  
RMS current  
Voltage peak  
Interval selections  
:
1, 3, 15, or 30 seconds, 1, 5, 10, 15, or  
30 minutes, 1 or 2 hours  
Current peak  
Event settings  
Event settings  
Effective power  
Apparent power  
Reactive power  
Power factor/Displacement power factor  
:
:
All measurement settings except  
flicker and inter-harmonics  
OFF or desired numerical value  
×
×
Event threshold value setting  
Maximum number of recording events  
×
×
:
100 (internal memory)  
(Simultaneous events count as 1 event.)  
Flicker (∆V10/Pst, Plt)  
Power supply  
:12 V DC from the 9458 AC ADAPTER or 9459 BATTERY PACK  
Maximum rated power  
Continuous operating time with battery : Approximately 30 minutes  
:
40 VA  
* Select from a total of six different patterns when recording data. These consist of three available data patterns  
(Power, P&Harm, or ALL DATA), combined with two patterns, AVE and ALL (maximum, minimum, and average), of  
detailed data for each measurement item.  
(9459 battery pack)  
External dimensions  
Mass  
:
Approximately 298W (11.73") × 215H (8.46") × 67D  
(2.64") mm (not including projections)  
:
Approximately 2.25 kg (79.4 oz.) (including 9459 battery pack)  
 复制成功!