欢迎访问ic37.com |
会员登录 免费注册
发布采购

3196 参数 Datasheet PDF下载

3196图片预览
型号: 3196
PDF下载: 下载PDF文件 查看货源
内容描述: 电力质量分析仪 [POWER QUALITY ANALYZER]
分类和应用:
文件页数/大小: 12 页 / 1902 K
品牌: ASM-SENSOR [ ASM GMBH ]
 浏览型号3196的Datasheet PDF文件第2页浏览型号3196的Datasheet PDF文件第3页浏览型号3196的Datasheet PDF文件第4页浏览型号3196的Datasheet PDF文件第5页浏览型号3196的Datasheet PDF文件第7页浏览型号3196的Datasheet PDF文件第8页浏览型号3196的Datasheet PDF文件第9页浏览型号3196的Datasheet PDF文件第10页  
6
Use event data to analyze the cause of power anomalies!  
Display the details for power anomalies captured using event triggers  
You can capture a variety of power anomalies by setting the individual trigger levels on the event setting screen.  
Captured data is displayed in the event list. This enables you to quickly confirm detailed data for phenomena (such  
as date/time, waveforms, RMS values, and harmonics), that are the source of problems, and effectively assess the  
cause of the problem.  
Set event triggers, start measurement  
Capture power anomalies Search list Display details  
Make event trigger settings and start measurement!  
1. Select a trigger threshold value that is suitable for the parameter being measured.  
Set thresholds along with other settings. You can make threshold settings while monitoring the actual input level, input waveform, and harmonics graph.  
Current input level  
Threshold setting  
value  
You can confirm the current input level.  
All trigger settings can be made at once, enabling accurate capture of complex power anomalies.  
When using the unit's internal memory to save events, up to 100 events are automatically saved, or up to 1000 events  
when using a PC card.  
Once measurement is finished, search the event list to confirm detailed data for events-even during measurement  
3. Confirm the number of captured events in the  
2. Confirm the details for events in the list screen.  
monitor screen.  
The capture date and event category are displayed.  
Select an event with  
the cursor and press  
the ENTER key  
The number of times each event occurred is visible at a glance.  
You can also check the events while they are being measured.  
Shows detailed data for the event that you selected  
with the cursor. (Date of occurrence, event type, level,  
continuous measurement period)  
Waveform display range:  
14 waveforms at 50 Hz  
16 waveforms at 60 Hz  
Simultaneously display voltage and current waveforms  
for instantaneous interruptions.  
Transient overvoltages up to 2000 Vpk with durations as low as  
0.5 µs are captured without fail.  
For  
transient  
capture  
Detailed  
transient values  
Cursor  
value  
Transient display range  
within 4 ms  
Confirm values using the cursor.  
Enlarge the transient waveform display.