ADV7123
Parameter
DAC PERFORMANCE
Glitch Impulse
DAC-to-DAC Crosstalk
Data Feedthrough
Clock Feedthrough
1
2
Min
Typ
10
23
22
33
Max
Unit
pV-sec
dB
dB
dB
These maximum/minimum specifications are guaranteed by characterization over the 4.75 V to 5.25 V range.
Note that the ADV7123 exhibits high performance when operating with an internal voltage reference, V
REF
.
3
DAC-to-DAC crosstalk is measured by holding one DAC high while the other two are making low-to-high and high-to-low transitions.
4
Clock and data feedthrough is a function of the amount of overshoot and undershoot on the digital inputs. Glitch impulse includes clock and data feedthrough.
5
TTL input values are 0 V to 3 V, with input rise/fall times of −3 ns, measured from the 10% and 90% points. Timing reference points are 50% for inputs and outputs.
3.3 V DYNAMIC SPECIFICATIONS
V
AA
= 3.0 V to 3.6 V
REF
= 1.235 V, R
SET
= 680 Ω, C
L
= 10 pF. All specifications are T
A
= 25°C, unless otherwise noted, T
J MAX
= 110°C.
Table 4.
Parameter
AC LINEARITY
Spurious-Free Dynamic Range to Nyquist
Single-Ended Output
f
CLK
= 50 MHz; f
OUT
= 1.00 MHz
f
CLK
= 50 MHz; f
OUT
= 2.51 MHz
f
CLK
= 50 MHz; f
OUT
= 5.04 MHz
f
CLK
= 50 MHz; f
OUT
= 20.2 MHz
f
CLK
= 100 MHz; f
OUT
= 2.51 MHz
f
CLK
= 100 MHz; f
OUT
= 5.04 MHz
f
CLK
= 100 MHz; f
OUT
= 20.2 MHz
f
CLK
= 100 MHz; f
OUT
= 40.4 MHz
f
CLK
= 140 MHz; f
OUT
= 2.51 MHz
f
CLK
= 140 MHz; f
OUT
= 5.04 MHz
f
CLK
= 140 MHz; f
OUT
= 20.2 MHz
f
CLK
= 140 MHz; f
OUT
= 40.4 MHz
Double-Ended Output
f
CLK
= 50 MHz; f
OUT
= 1.00 MHz
f
CLK
= 50 MHz; f
OUT
= 2.51 MHz
f
CLK
= 50 MHz; f
OUT
= 5.04 MHz
f
CLK
= 50 MHz; f
OUT
= 20.2 MHz
f
CLK
= 100 MHz; f
OUT
= 2.51 MHz
f
CLK
= 100 MHz; f
OUT
= 5.04 MHz
f
CLK
= 100 MHz; f
OUT
= 20.2 MHz
f
CLK
= 100 MHz; f
OUT
= 40.4 MHz
f
CLK
= 140 MHz; f
OUT
= 2.51 MHz
f
CLK
= 140 MHz; f
OUT
= 5.04 MHz
f
CLK
= 140 MHz; f
OUT
= 20.2 MHz
f
CLK
= 140 MHz; f
OUT
= 40.4 MHz
Spurious-Free Dynamic Range Within a Window
Single-Ended Output
f
CLK
= 50 MHz; f
OUT
= 1.00 MHz; 1 MHz Span
f
CLK
= 50 MHz; f
OUT
= 5.04 MHz; 2 MHz Span
f
CLK
= 140 MHz; f
OUT
= 5.04 MHz; 4 MHz Span
Double-Ended Output
f
CLK
= 50 MHz; f
OUT
= 1.00 MHz; 1 MHz Span
f
CLK
= 50 MHz; f
OUT
= 5.00 MHz; 2 MHz Span
f
CLK
= 140 MHz; f
OUT
= 5.00 MHz; 4 MHz Span
Rev. D | Page 6 of 24
Min
Typ
Max
Unit
67
67
63
55
62
60
54
48
57
58
52
41
70
70
65
54
67
63
58
52
62
61
55
53
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
77
73
64
74
73
60
dBc
dBc
dBc
dBc
dBc
dBc