MIL-PRF-38535K
APPENDIX A
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO) STANDARDS
ISO 14644-1
ISO 14644-2
- Clean rooms and Associated Controlled Environments – Part 1: Classification of Air
Cleanliness.
- Clean rooms and Associated Controlled Environments – Part 2: Specifications for
Testing and Monitoring to Prove Continued Compliance with ISO 14644-1.
(Copies of these documents are available online at http://www.iest.org/ or from Institute of Environmental Sciences
and Technology (IEST), 940 East Northwest Highway, Mount Prospect, IL 60056-3444.)
SOCIETY OF AUTOMOTIVE ENGINEERS (SAE)
SAE-AMS-I-23011
- Iron-Nickel Alloys for Sealing to Glasses and Ceramics.
(Copies of this document are available online at http://www.sae.org/ or from Society of Automotive Engineers, 400
Commonwealth Dr., Warrendale, PA 15096-0001.)
(Non-Government standards and other publications are normally available from the organizations that prepare or
distribute the documents. These documents also may be available in or through libraries or other informational
services.)
A.2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the
text of this document and the references cited herein (except for related specification sheets), the text of this
document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless
a specific exemption has been obtained.
A.3 REQUIREMENTS
A.3.1 General. The manufacturer of microcircuits in compliance with this appendix shall have and use production
and test facilities and a quality and reliability assurance program adequate to assure successful compliance with the
provisions of this appendix, the manufacturer's baseline (DSCC-VQC-42 or equivalent) and the device specification
or drawing. The individual item requirements shall be as specified herein, and in accordance with the device
specification or drawing.
The requirements of this appendix, or 1.2.1 of MIL-STD-883 are met or exceeded by product built to a QML certified
flow by a QA certified and qualified manufacturer or by a manufacturer who has been granted transitional certification
to MIL-PRF-38535. The QML flow as documented in the QM plan allows modification to processes and tests used in
producing QML devices (See J.3.12 herein). These changes shall not affect the form, fit, function or radiation
hardness assurance level (when applicable) of any QML devices. These devices are marked with the "Q" or "QML"
certification mark to reflect the QML flow used.
A.3.1.1 Reference to device specification or drawing. For purposes of this appendix, when the term "as specified"
is used without additional reference to a specific location or document, the intended reference shall be to the device
specification or drawing which constitutes the applicable individual device specification.
48