EAGLE
PRELIMINARY
Ver 1.3
3.7.8 CRT Display Current X / Y Position Register(CRTXY)
Display Current X Position register is a read-only register. It indicates Horizontal Counter value.
Display Current Y Position register is also a read-only register. It indicates Vertical Counter value.
Address : FFE0 141Ch
Bit
R/W
R
R
R
R
Description
Default Value
31 : 27
26 : 16
15 : 11
10 : 0
Reserved
-
This field contains the value of the vertical counter.
Reserved
This field contains the value of the horizontal counter.
000h
-
000h
3.7.9 CRT Status Register(CRTSTAT)
The read-only CRT Status Register bit[7:0] is indicates the status of CRT controller.
Horizontal Sync and Vertical Sync signals are set to active low status when Control Register[21:20] bits are “00”. When
Control Register[21:20] Bits are “11”, both Sync signals are set to active high status.
Horizontal / Vertical Active signal is set to active high regardless of the value of Control Register[21:20] bits.
Address : FFE0 1420h
Bit
31 : 8
R/W
R
Description
Default Value
Reserved
-
7
6 : 5
4
3
2
R
R
R
R
R
R
R
External Sync. Detect
Current Display Bank
Field ( 1 : ODD Field, 0 : EVEN Field )
Vertical Active (active high)
Vertical Sync
0b
00b
1b
0b
1b
0b
1b
1
0
Horizontal Active (active high) .
Horizontal Sync
Beijing Peak Microtech Co.Ltd.
CONFIDENTIAL
88