RTL8211C & RTL8211CL
Datasheet
7.3.5. INER (Interrupt Enable Register, Address 0x12)
Table 35. INER (Interrupt Enable Register, Address 0x12)
Bit
Name
RW
RW
RW
RW
RW
RW
Default Description
18.15 Auto-Negotiation Error Interrupt
18.14 Speed Change Interrupt
0
0
0
0
0
1: Interrupt enable
0: Interrupt disable
0: Interrupt disable
0: Interrupt disable
0: Interrupt disable
0: Interrupt disable
1: Interrupt enable
1: Interrupt enable
1: Interrupt enable
1: Interrupt enable
18.13 Duplex Mode Change Interrupt
18.12 Page Received Interrupt
18.11 Auto-Negotiation Completed
Interrupt
18.10 Link Status Change Interrupt
RW
RW
RW
RW
RW
RW
RW
RW
0
0
0
0
0
0
0
0
1: Interrupt enable
1: Interrupt enable
1: Interrupt enable
Reserved.
0: Interrupt disable
0: Interrupt disable
0: Interrupt disable
18.9
18.8
18.7
18.6
Symbol Error Interrupt
False Carrier Interrupt
RSVD
MDI Crossover Change Interrupt
1: Interrupt enable
Reserved.
0: Interrupt disable
18.5:2 RSVD
18.1
18.0
Polarity Change Interrupt
Jabber Interrupt
1: Interrupt enable
1: Interrupt enable
0: Interrupt disable
0: Interrupt disable
7.3.6. INSR (Interrupt Status Register, Address 0x13)
Table 36. INSR (Interrupt Status Register, Address 0x13)
Bit
Name
RW Default Description
19.15 Auto-Negotiation Error
19.14 Speed Change
RC
RC
RC
RC
0
0
0
0
1: Auto-Negotiation Error
1: Link speed changed
0: No Auto-Negotiation Error
0: Link speed not changed
0: Duplex mode not changed
19.13 Duplex Mode Change
19.12 Page Received
1: Duplex mode changed
1: Page (a new LCW) received
0: Page not received
19.11 Auto-Negotiation Completed
19.10 Link Status Change
RC
0
1: Auto-Negotiation completed
0: Auto-Negotiation not completed
RC
RC
RC
RC
RC
0
0
0
0
0
1: Link status changed
1: Symbol error detected
1: False carrier
0: Link status not changed
19.9
19.8
19.7
19.6
Symbol Error
False Carrier
0: No symbol error detected
0: No false carrier detected
RSVD
Reserved.
MDI Crossover Change
1: Crossover status changed
0: Crossover status not changed
19.5:2 RSVD
RC
RC
0000 Reserved.
19.1
Polarity Change
0
1: Polarity Changed
0: Polarity not changed
Note: This bit is valid only when 1000Base-T is enabled.
19.0
Jabber
RC
0
1: Jabber detected
0: No jabber detected
Integrated 10/100/1000 Gigabit Ethernet Transceiver
32
Track ID: JATR-1076-21 Rev. 1.3